S'abonner

Pilot study on the sensitivity and specificity of in vivo reflectance confocal microscopy in the diagnosis of allergic contact dermatitis - 21/08/11

Doi : 10.1016/j.jaad.2005.08.026 
Susanne Astner, MD a, Ernesto Gonzalez, MD b, Arnold Cheung, MD a, Francisca Rius-Diaz, PhD a, Salvador González, MD, PhD a, c,
a From Wellman Center for Photomedicine, Department of Dermatology, Massachusetts General Hospital, Harvard Medical School, Boston 
b Contact Dermatitis Unit, Department of Dermatology, Massachusetts General Hospital, Boston 
c Dermatology Service, Memorial Sloan Kettering Cancer Center, New York 

Reprint requests: Salvador Gonzalez MD, PhD, Memorial Sloan Kettering Cancer Center, Dermatology Service (2nd Floor), Rockefeller Outpatient Pavilion, 160 E 53rd St, New York, NY 10022.

Boston, Massachusetts, and New York, New York

Abstract

The validity, reproducibility, and specificity of patch-testing in the diagnosis of allergic contact dermatitis (ACD) have repeatedly been addressed. In vivo reflectance confocal microscopy (RCM) has been used for real-time evaluation of the histopathologic features of ACD. This pilot study was designed to determine the sensitivity and specificity of RCM in diagnosing ACD in reference to patch-testing. Sixteen participants were patch tested with allergens and control substances. Clinical scoring, digital photography, and RCM evaluation were performed at 72 hours, and RCM images were subjected to blinded evaluation. RCM evaluation parameters included stratum corneum (SC) disruption, parakeratosis, stratum spinosum (SS) and stratum granulosum (SG) spongiosis, and exocytosis. Overall, there was high specificity for all RCM features, ranging from 95.8% to 100%. Sensitivity ranged from 51.9% to 96.3%. Significant parameters with high sensitivity and specificity included spongiosis and exocytosis at the level of SS. Logistic regression analysis was performed on significant variables; P values were determined by χ2 analysis. RCM is a promising noninvasive technology for the evaluation of ACD. SC changes are not helpful in the diagnosis of ACD, although the presence of SG spongiosis and SS spongiosis shows high sensitivity in diagnosing ACD. Larger sensitivity and specificity studies are needed and the identification of ACD has to be based on a defined diagnostic algorithm. A limitation of this study is the small sample size; larger sensitivity and specificity studies are needed to confirm these findings. In addition, individual allergens have to be subjected to further evaluations in order to demonstrate the applicability of our findings for other contact allergens. In that regard, RCM may be considered as an adjunctive tool, rather than a substitute, to clinical evaluation.

Le texte complet de cet article est disponible en PDF.

Abbreviations used : ACD, CD, ICD, RCM, SC, SG, SS


Plan


 Funding source: R01 grant from the National Institutes of Health (to S. G.).
Conflicts of interest: None identified.


© 2005  American Academy of Dermatology, Inc.. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 53 - N° 6

P. 986-992 - décembre 2005 Retour au numéro
Article précédent Article précédent
  • Reflectance-mode confocal microscopy of pigmented skin lesions–improvement in melanoma diagnostic specificity
  • Giovanni Pellacani, Anna Maria Cesinaro, Stefania Seidenari
| Article suivant Article suivant
  • Soft x-ray therapy for cutaneous basal cell and squamous cell carcinomas
  • Klaus-Werner Schulte, Andrea Lippold, Christine Auras, Gernot Bramkamp, Claudia Breitkopf, Heinz-Joachim Elsmann, Eva Maria Habenicht, Volker Jasnoch, Helga Müller-Pannes, Rainer Rupprecht, Ludwig Suter

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.