S'abonner

Prospective randomized comparison of early and late results of a carbonized stent versus a high-grade stainless steel stent of identical design: The Prevention of Recurrent Venous Thromboembolism (PREVENT) trial - 21/08/11

Doi : 10.1016/j.ahj.2004.07.011 
Peter B. Sick, MD a, , Oana Brosteanu, PhD b, Matthias Ulrich a, Holger Thiele, MD a, Josef Niebauer, MD, PhD a, Ingmar Busch, MD c, Gerhard Schuler, MD a
a Department of Internal Medicine/Cardiology, Heart Center, University of Leipzig, Leipzig, Germany 
b Coordination Center for Clinical Trials, University of Leipzig, Leipzig, Germany 
c Department of Internal Medicine, Cardiology, St. Elisabeth Hospital, Halle, Germany 

 Reprint requests: Peter B. Sick, MD, Department for Cardiology, Heart Center GmbH, University of Leipzig, Struempellstraße 39, 04289 Leipzig, Germany.

Résumé

Background

Restenosis after coronary interventions with stent implantation is still the main obstacle of interventional cardiology. The aim of this study was to compare a carbonized and high-grade stainless steel stent of identical design with regard to early and late adverse events.

Methods

In this prospective randomized trial the carbonized MAC stent (amg GmbH, Raesfeld-Erle, Germany) was compared with the stainless steel MAC stent of identical design. Primary end point was diameter stenosis at follow-up; secondary end points were angiographic parameters, rate of restenosis, and major cardiac adverse events (MACE; myocardial infarction, reintervention, and death).

Results

Between August 1999 and June 2002, 396 patients were randomized in 2 centers of Germany. Diameter stenosis at follow-up (38.6% ± 23.4% vs 39.1% ± 22.2%, P = .49) as primary end point, relative late lumen loss (26.8% ± 23.7% vs 27.7% ± 22.3%, P = .26), absolute late lumen loss (0.92 ± 0.71 vs 0.92 ± 0.66 mm, P = .58), net gain (1.4 ± 0.8 vs 1.4 ± 0.8 mm, P = .96), as well as restenosis rates (18.0% vs 19.0%, P = .81) and MACE (13.5% vs 12.2%, P = .71) were not significantly different between the carbonized and the pure stainless steel study arm, respectively.

Conclusion

The hypothesis of superiority of the carbonized stent over a stainless steel stent of identical design with regard to restenosis and MACE could not be proved. Inactive coating of stents seems to have no advantage over pure stainless steel stents, which was also demonstrated in other trials. The future probably lies in active coating of stents with drugs that reduce the neointimal proliferation process.

Le texte complet de cet article est disponible en PDF.

Plan


© 2005  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 149 - N° 4

P. 681-688 - avril 2005 Retour au numéro
Article précédent Article précédent
  • The role of platelet glycoprotein IIIa polymorphism in the high prevalence of in vitro aspirin resistance in patients with intracoronary stent restenosis
  • Burak Pamukcu, Huseyin Oflaz, Yilmaz Nisanci
| Article suivant Article suivant
  • Two-year clinical follow-up of 90Sr/90 Y ?-radiation versus placebo control for the treatment of in-stent restenosis
  • Sigmund Silber, Jeffrey J. Popma, Mohan Suntharalingam, Alexandra J. Lansky, Richard R. Heuser, Burton Speiser, Paul S. Teirstein, Theodore Bass, William O'Neill, John Lasala, Mark Reisman, Samin K. Sharma, Richard E. Kuntz, Raoul Bonan, for the START Investigators

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.