S'abonner

Incidence and predictors of restenosis after sirolimus-eluting stent implantation in high-risk patients - 21/08/11

Doi : 10.1016/j.ahj.2004.10.009 
Alberto Berenguer, MD a, , Vicente Mainar, MD a, Pascual Bordes, MD a, Jose Valencia, MD a, Silvia Gómez, BS a, Teresa Lozano, MD b
a Cardiology Service, General Hospital of Alicante, Spain 
b Cardiology Section, Hospital Marina Baixa, Villajoyosa, Spain 

Reprint requests: Alberto Berenguer Jofresa, MD, Servicio de Cardiología, Hospital General de Alicante, Avda. Maestro Alonso S/N, 03010 Alicante, Spain.

Résumé

Background

Sirolimus-eluting stents (SESs) have not been evaluated systematically in clinical scenarios or with the vascular morphologies associated with the highest rates of restenosis.

Methods

Between May 2002 and August 2003, 1379 percutaneous interventions were carried out at our center, 231 with SES implantation in patients with complex coronary lesions: (1) left main trunk, (2) bifurcations, (3) long lesions, (4) calcified lesions, (5) proximal segment of the left anterior descending coronary, (6) restenotic lesions, (7) total occlusions, (8) ostial lesions, and (9) vessels <2.75 mm. Angiographic follow-up was carried out in the 6th month in 201 patients. Clinical, angiographic, and procedural variables were analyzed to assess predictors of restenosis.

Results

Of the patients, 42.6% were diabetic and 20.2% were insulin dependent. A total of 263 lesions was treated. Mean lesion length was 16.5 ± 11 mm and mean vessel diameter was 2.54 ± 0.7 mm. A total of 327 stents was implanted to fully cover the entire lesion, in most cases after predilatation (89.1%). The mean segment length covered by the stent was 26 ± 12 mm and the stent length/lesion length ratio was 1.7 ± 0.9. Binary restenosis was found in 8.7%, but there was no edge restenosis. The only predictors of restenosis were female sex (OR 3.44, 95% CI 1.31-8.99, P = .011) and lesion length >30 mm (OR 3.39, 95% CI 1.07-10.77, P = .038).

Conclusions

In scenarios that usually entail high restenotic risk in patients with conventional stent implantation, SESs had a low incidence of restenosis without edge complications.

Le texte complet de cet article est disponible en PDF.

Plan


© 2005  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 150 - N° 3

P. 536-542 - septembre 2005 Retour au numéro
Article précédent Article précédent
  • Magnetic resonance angiography of coronary arteries with a 3-dimensional magnetization-prepared true fast imaging with steady-state precession sequence compared with conventional coronary angiography
  • Nina Man-ching So, Wynnie Wai-man Lam, Debiao Li, Anna Kin-Yin Chan, John Elsby Sanderson, Constantine Metreweli
| Article suivant Article suivant
  • Radial versus femoral access for emergent percutaneous coronary intervention with adjunct glycoprotein IIb/IIIa inhibition in acute myocardial infarction—the RADIAL-AMI pilot randomized trial
  • Warren J. Cantor, Geoff Puley, Madhu K. Natarajan, Vlad Dzavik, Mina Madan, Anne Fry, Hahn Hoe Kim, James L. Velianou, Nurry Pirani, Bradley H. Strauss, Robert J. Chisholm

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.