The relationship between electrical axis by 12-lead electrocardiogram and anatomical axis of the heart by cardiac magnetic resonance in healthy subjects - 21/08/11

Doi : 10.1016/j.ahj.2004.10.041 
Henrik Engblom, MD a, John E. Foster, PhD b, Thomas N. Martin, MD b, Bjoern Groenning, MD b, Olle Pahlm, MD, PhD a, Henry J. Dargie, MD, PhD b, Galen S. Wagner, MD c, Håkan Arheden, MD, PhD a,
a Department of Clinical Physiology, Lund University Hospital, Lund, Sweden 
b Glasgow Cardiac Magnetic Resonance Unit, Glasgow, Lanarkshire, UK 
c Duke University Medical Center, Durham, NC 

Reprint requests: Håkan Arheden, MD, PhD, Department of Clinical Physiology, Lund University Hospital, S-221 85 Lund, Sweden.

Financial support: Swedish Medical Research Council, Swedish Heart Lung Foundation, British Heart Foundation, The Medical Faculty, Lund University.

Résumé

Background

The traditional assumption has been that there is a close relationship between the electrical and anatomical axes of the heart. The aim of this study was to test the hypothesis that there is a correlation between the electrical and anatomical axes of the heart, in both the frontal and transverse planes, in healthy subjects.

Methods

Ninety-four healthy volunteers (48 men, 46 women; age 21-82 years) were studied by cardiac magnetic resonance and 12-lead electrocardiogram. The anatomical axis was determined by cardiac magnetic resonance and projected onto the frontal and transverse orthogonal planes for comparison with the electrical axis in the corresponding planes.

Results

The electrical and anatomical axes were in the same range in the frontal plane (mean ± SD, +39° ± 31° and +38° ± 10°), but in different ranges in the transverse plane (mean ± SD, −30° ± 18° and +46° ± 7°). The partial correlation coefficients between electrical and anatomical axes were r = 0.30 (P < .01) and r = 0.14 (P = NS) in the frontal and transverse planes, respectively. Age was more strongly correlated to electrical axis than to anatomical axis in the frontal plane.

Conclusions

There is only a weak correlation between electrical and anatomical axes in the frontal plane and no correlation in the transverse plane. The change of electrical axis with increased age is not explained only by change in the anatomical axis. The results suggest that there is no simple relationship between the electrical and anatomical axes of the heart.

Le texte complet de cet article est disponible en PDF.

Plan


© 2005  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 150 - N° 3

P. 507-512 - septembre 2005 Retour au numéro
Article précédent Article précédent
  • Creation of a large-scale genetic data bank for cardiovascular association studies
  • Ramtin Agah, Stephen Ellis, Sue Chase, Mark Henderson, Lisa Mlady, Gurunathan Murugesan, Raymond Tubbs, Kandice Marchant, Ilka Warshawsky, Colleen Rouse, Kathy Hughes, Patricia Welch, Eric J. Topol
| Article suivant Article suivant
  • The prevalence of bicuspid aortic valve in newborns by echocardiographic screening
  • Ercan Tutar, Filiz Ekici, Semra Atalay, Nazire Nacar

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.