S'abonner

Transcatheter Closure of Congenital Ventricular Septal Defect with Amplatzer Septal Occluders - 21/08/11

Doi : 10.1016/j.amjcard.2005.09.068 
Mario Carminati, MD , Gianfranco Butera, MD, Massimo Chessa, MD, Manuela Drago, MD, Diana Negura, MD, Luciane Piazza, MD
Pediatric Cardiology Center, Policlinico San Donato, Milan, Italy. 

Address for reprints: Mario Carminati, MD, Pediatric Cardiology, Policlinico San Donato, Via Morandi 30, 20097 San Donato, Milan, Italy.

Résumé

This study reports on experience with transcatheter closure of congenital ventricular septal defects (VSDs) with Amplatzer septal occluders. From January 2000 to April 2005, transcatheter Amplatzer device implantation was attempted in 122 patients with congenital VSD (30 with muscular, 87 with perimembranous, and 5 with residual postsurgical repair of conotruncal malformations). Patient mean age was 15 years (range, 6 months to 64 years), and mean weight was 35 kg (range, 5.8 to 102 kg). The VSD mean size was 7 mm (range, 4 to 16 mm), mean Qp/Qs was 2.1 (range, 1.3 to 4), and mean fluoroscopy time was 32 minutes (range, 5 to 129 minutes). All procedures were performed with the patient under general anesthesia and guided by fluoroscopy and transesophageal echocardiography. The device size chosen was usually 1- to 2-mm larger than the maximum defect size as assessed by either the echocardiographic or angiographic views that were judged most reliable. Amplatzer muscular devices were placed in 47 patients, and the membranous devices were placed in 72 patients. The procedure was not performed in 3 patients with perimembranous VSD because of the impossibility of achieving an adequate long sheath position in 1 patient, onset of complete atrioventricular (AV) block during catheter manipulation in 1 patient, and the presence of aortic valve prolapse preventing a safe device placement in 1 patient. Satisfactory device implantation was achieved in 119 of 122 patients (97.5%): a tiny smoke-like residual flow through the device was often seen immediately after the procedure (50%); residual shunting was detectable in 19% after 24 hours and in only 4% at 6 months. The following additional catheter interventions were performed simultaneously: balloon pulmonary valvuloplasty in 3 patients, device closure of atrial septal defects in 2 patients, coil occlusion of the arterial duct in 1 patient, stenting coarctation in 1 patient, and stenting of the right pulmonary artery in 1 patient. Minimal aortic regurgitation developed in 3 patients, and minimal tricuspid regurgitation in 3 patients; no patient required additional treatment. Device embolization occurred in 3 patients (1 patient with muscular VSD, 2 with perimembranous VSD); catheter retrieval and implantation of a second device was successfully performed in all patients. Transient left bundle branch block occurred in 2 patients, and transient first-degree AV block in 1 patient. Among the perimembranous VSD cases, complete AV block occurred acutely (within 48 hours) in 3 patients, requiring a pacemaker in 1 patient; complete heart block occurred in the other 2 patients after 5 and 12 months, requiring pacemakers. There was no mortality. Transcatheter closure of muscular and perimembranous VSDs offers encouraging results: 96% complete closure at midterm follow-up. Complications are limited; the most relevant appears to be device-related complete heart block in perimembranous VSD. Greater experience and long-term follow-up are required to assess the safety and effectiveness of this procedure as an alternative to conventional surgery.

Le texte complet de cet article est disponible en PDF.

Plan


© 2005  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 96 - N° 12S1

P. 52-58 - décembre 2005 Retour au numéro
Article précédent Article précédent
  • The Emerging Role of Echocardiography in the Screening of Patients at Risk of Heart Failure
  • Paolo Colonna, Fausto J. Pinto, Margherita Sorino, Francesco Bovenzi, Carlo D’Agostino, Italo de Luca
| Article suivant Article suivant
  • Atrial Fibrillation Ablation: State of the Art
  • Carlo Pappone, Vincenzo Santinelli

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.