Agreement and Repeatability for Standard Automated Perimetry and Confocal Scanning Laser Ophthalmoscopy in the Diagnostic Innovations in Glaucoma Study - 19/08/11

Doi : 10.1016/j.ajo.2006.04.027 
Diana Ng, MD, Linda M. Zangwill, PhD, Lyne Racette, PhD, Christopher Bowd, PhD, John P. Pascual, MA, Rupert R.A. Bourne, MD, Catherine Boden, PhD, Robert N. Weinreb, MD, Pamela A. Sample, PhD
Hamilton Glaucoma Center Department of Ophthalmology, University of California at San Diego, La Jolla, California. 

Inquiries to: Pamela A. Sample, PhD, Department of Ophthalmology, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92093

Résumé

Purpose

To assess agreement between structural and functional testing in classifying eyes as normal or abnormal and their repeatability on two consecutive visits by means of standard automated perimetry (SAP) and confocal scanning laser ophthalmoscopy.

Design

Analysis of selected data obtained from a prospective longitudinal observational cohort study, the Diagnostic Innovations in Glaucoma Study.

Methods

One hundred fifty-one participants with a SAP and a Heidelberg Retina Tomograph (HRT) test within a three-month window at two visits within 15 months were included. Eyes were classified by SAP and HRT at each visit. Agreement and repeatability were assessed by κ statistics.

Results

At visit 1, 33 (22%) of 151 eyes had only SAP defects, 11 (7%) eyes had only HRT defects, and 35 (23%) eyes had both SAP and HRT defects. Seventy-two eyes (48%) were classified as normal by both tests. Similar results were obtained for visit 2. The agreement between SAP and HRT in classifying eyes was 70% (κ = 0.393) at visit one and 68% (κ = 0.363) at visit 2. Repeatability of classification by SAP alone, HRT alone, and both SAP and HRT between visits 1 and 2 was 84% (κ = 0.693), 89% (κ = 0.752), and 90% (κ = 0.723), respectively.

Conclusions

Agreement between SAP and HRT was only fair at both visits. Repeatability across visits was substantial for SAP alone, HRT alone, and for the combination of SAP and HRT. These results suggest that detection of particular features of glaucomatous damage depends on the technique used. Structural and functional tests appear complementary, and both should be used for early detection of glaucoma.

Le texte complet de cet article est disponible en PDF.

Plan


 Supported in part by National Eye Institute grants EY11008 (L.M.Z.) and EY08208 (P.A.S.). Alcon Laboratories Inc, Allergan, Pfizer Inc, and SANTEN Inc. Research funding or materials from Carl Zeiss Meditec (P.A.S., L.M.Z., R.N.W.), Heidelberg Engineering (P.A.S., L.M.Z., R.N.W., R.R.A.B.), Welch-Allyn (P.A.S.), and Haag-Streit (P.A.S.); honoraria from Heidelberg Engineering (L.M.Z., R.N.W.) and Carl Zeiss Meditec (R.N.W.).


© 2006  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 142 - N° 3

P. 381-386 - septembre 2006 Retour au numéro
Article précédent Article précédent
  • Measurements of Optic Disk Size With HRT II, Stratus OCT, and Funduscopy Are Not Interchangeable
  • Yaniv Barkana, Noga Harizman, Yariv Gerber, Jeffrey M. Liebmann, Robert Ritch
| Article suivant Article suivant
  • Fluidics and Heat Generation of Alcon Infiniti and Legacy, Bausch & Lomb Millennium, and Advanced Medical Optics Sovereign Phacoemulsification Systems
  • Michael S. Floyd, Jeremy R. Valentine, Randall J. Olson

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.