Résumé

Purpose

The effectiveness of diffusion trace value analysis for non-invasive assessment of retinal ganglion cell (RGC) axonal degeneration at multiple anatomic levels along the human visual pathway under clinical setting was evaluated.

Design

Imaging study.

Methods

Ten patients with unilateral chronic optic neuropathy of varying cause and 16 age-matched normal subjects were studied. Trace, a tensor invariant that is considered to be a sensitive index for pathologic changes in axons, was analyzed at nine anatomic sites in each subject, namely, bilaterally at the level of the optic nerves, uncrossed chiasmal fibers, optic tracts and optic radiations, and crossed chiasmal fibers, using a 3.0 Tesla magnetic resonance imaging system.

Results

Trace values of the optic nerve and uncrossed chiasmal fibers ipsilateral to the affected eye, the crossed chiasmal fibers, and optic tracts bilaterally were significantly higher than those of the corresponding anatomic sites in normal subjects. The optic nerve and uncrossed chiasmal fibers ipsilateral to the unaffected side and optic radiations, bilaterally, had trace values which were not significantly different from the values of the corresponding anatomic levels in normal subjects. The increase in trace value in the optic nerve and uncrossed chiasmal fibers ipsilateral to the affected side was greater than those of the crossed chiasmal fibers and optic tracts.

Conclusions

Findings are highly consistent with a degenerative process of RGC axons and trace values are quantitatively well correlated to predicted pathology at the given anatomical sites. Trace value measurement at multiple sites along fiber pathways appears to be a powerful addition to clinical assessment of the functionality of components of the visual pathways during various stages of a pathologic process.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.
Supported by Ministry of Education, Culture, Sports, Science, and Technology (Japan).


© 2006  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 142 - N° 4

P. 591 - octobre 2006 Retour au numéro
Article précédent Article précédent
  • Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Glaucoma Patients and Healthy Subjects
  • Lorenz Barleon, Esther M. Hoffmann, Manfred Berres, Norbert Pfeiffer, Franz H. Grus
| Article suivant Article suivant
  • Measurement of the Actual Dose of Triamcinolone Acetonide Delivered by Common Techniques of Intravitreal Injection
  • Michael D. Ober, Gaetano R. Barile, Samir R. Tari, Gian M. Tossi, William M. Schiff, Stanley Chang

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.