S'abonner

Quality control for handling of accidental blood exposures - 18/08/11

Doi : 10.1016/j.jhin.2006.02.006 
P.Th.L. van Wijk a, b, , M. Pelk-Jongen a, C. Wijkmans b, A. Voss c, d, P.M. Schneeberger a
a Department of Medical Microbiology and Infection Control, Jeroen Bosch Hospital, 's-Hertogenbosch, The Netherlands 
b Department of Infectious Diseases and Public Health, Hart voor Brabant, 's-Hertogenbosch, The Netherlands 
c Department of Medical Microbiology and Infectious Diseases, Canisius-Wilhelmina Hospital, Nijmegen, The Netherlands 
d Nijmegen University Centre for Infectious Diseases, Radboud University Medical Centre, Nijmegen, The Netherlands 

Corresponding author. Address: Department of Medical Microbiology and Infection Control, Jeroen Bosch Hospital, PO Box 90153, 5200 ME 's-Hertogenbosch, The Netherlands. Tel.: +31 73 6992954; fax: +31 73 6992875.

Summary

A regional counselling service was established to handle all accidental blood exposures using a standardized protocol. Levels of risk were assessed using an algorithm. Accidents that posed a risk for the transmission of hepatitis B (HBV), hepatitis C (HCV) and human immunodeficiency virus (HIV) were classified as ‘high risk’, whereas accidents that posed a risk for HBV alone were classified as ‘low risk’. Medical interventions were implemented according to the level of risk. During a one-year period, all accidents were registered and analysed for adherence to the standard protocol. In 2003, the centre handled 454 incidents. Of these, 36 (7.9%) incidents were assessed as no risk, 329 (72.5%) were assessed as low risk, and 67 (14.8%) were assessed as high risk. Due to incomplete registration, 22 (4.8%) incidents could not be analysed further. In total, 36% of the incidents with risk for HBV transmission and 40% of the incidents with risk for HCV and HIV transmission were not handled according to the proposed protocol. Breaches consisted of over-reaction (25/396) as well as insufficient response (123/396). Potentially inadequate treatment occurred for HIV postexposure prophylaxis in 12 of 63 incidents. Incomplete follow-up for HCV occurred in 11 of 63 incidents, and lack of HBV immunoglobulin administration occurred in five of 396 incidents, including three high-risk incidents. In 21 of 396 low-risk exposures, the breaches in protocol resulted from late reporting. It remains difficult to achieve an acceptable level of standardized care when using standard operational procedures. Documentation and evaluation of flaws are essential to improve the system.

Le texte complet de cet article est disponible en PDF.

Keywords : Accidental blood exposures, Bloodborne pathogens, Quality improvement


Plan


© 2006  The Hospital Infection Society. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 63 - N° 3

P. 268-274 - juillet 2006 Retour au numéro
Article précédent Article précédent
  • Needlestick injuries during medical training
  • S. Deisenhammer, K. Radon, D. Nowak, J. Reichert
| Article suivant Article suivant
  • Risk of conjunctival contamination in total joint arthroplasty
  • B.I. Singh, H. Nurein, S. Sinha, S. Singh, P. Housden

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.