S'abonner

Role of probucol in inhibiting intimal hyperplasia after coronary stent implantation: A randomized study - 18/08/11

Doi : 10.1016/j.ahj.2006.05.005 
Gilberto L. Nunes, MD, PhD a, , Alexandre C. Abizaid, MD, PhD b, Marcus P. Theodoro, MD, Fábio S. Brito, MD, PhD c, Adriano Caixeta, MD, PhD d, Luís Felipe F. da Silva e, Nicolle G. Mazzotti, BSci e, Adriane Belló-Klein, PhD e, Nadine Clausell, MD, PhD f
a Interventional Cardiology Department, Hospital São Francisco, Porto Alegre, Brazil 
b Institute Dante Pazzanese of Cardiology, São Paulo, Brazil 
c Federal University of São Paulo and Hospital Israelita Albert Einstein, São Paulo, Brazil 
d Hospital Barra D'Or, Rio de Janeiro, Brazil 
e Cardiovascular Physiology Laboratory, Department of Physiology, Federal University of Rio Grande do Sul, Porto Alegre, Brazil 
f Program of Post-Graduation in Health Sciences: Cardiology and Cardiovascular Sciences, Federal University of Rio Grande do Sul, Porto Alegre, Brazil 

Reprint requests: Gilberto L. Nunes, MD, PhD, Director, Interventional Cardiology and Cardiac Catheterization Laboratory, Hospital São Francisco, Rua Prof Annes Dias 285, Porto Alegre, RS, 90020-090 Brazil.

Résumé

Background

Oxygen-free radicals can stimulate smooth muscle cell proliferation and may therefore be involved in the genesis of in-stent restenosis. Thus, treatment with probucol, a potent antioxidant agent that has been shown to reduce restenosis after balloon angioplasty, may be an effective strategy to prevent intimal hyperplasia after stenting.

Methods

In a prospective double-blind study, 59 patients submitted to coronary stent implantation were randomly assigned to treatment with either probucol (1 g/d) or placebo, starting two weeks before the procedure and continued for 6 months. The primary end point was the intimal hyperplasia volume at 6 months measured by intravascular ultrasound (IVUS) imaging.

Results

Of the 59 randomized patients, 54 underwent successful stent implantation, completed the follow-up period, and underwent repeat angiography, 6.1 ± 1.1 months after the procedure. Volumetric IVUS analysis revealed similar intimal hyperplasia volumes (403 ± 26.7 mm3 for probucol vs 44.8 ± 28.3 mm3 for placebo) and percent volume obstruction of the lumen (30.4% ± 14.5% for probucol versus 30.7% ± 17.2% for placebo) in both groups. In addition, quantitative coronary angiography showed no differences in late loss (1.0 ± 0.8 mm vs 1.1 ± 0.8 mm), loss index (0.5 ± 0.4 for both groups), or angiographic restenosis rates (19.4% vs 18.5%) between the probucol and placebo groups, despite the observation of significant changes in the lipid profile and in the plasma antioxidant defenses in patients receiving probucol.

Conclusions

Treatment with the antioxidant probucol failed to reduce neointimal formation after coronary stent implantation as assessed by IVUS volumetric analysis.

Le texte complet de cet article est disponible en PDF.

Plan


© 2006  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 152 - N° 5

P. 914.e1-914.e7 - novembre 2006 Retour au numéro
Article précédent Article précédent
  • Nonemergent percutaneous coronary interventions in a veterans affairs medical center without onsite cardiac surgery
  • Oleg Roussanov, Greta Estacio, Maribeth Capuno, Linda Archuleta, Judith Hill, Nabil F. Jarmukli
| Article suivant Article suivant
  • Comparison between stenting and balloon angioplasty in patients undergoing primary angioplasty of small coronary vessels
  • Giuseppe De Luca, Harry Suryapranata, Arnoud W.J. van't Hof, Jan Paul Ottervanger, Jan C.A. Hoorntje, Jan-Henk Dambrink, A.T. Marcel Gosselink, Menko-Jan de Boer

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.