S'abonner

Survival in octogenarians receiving implantable defibrillators - 18/08/11

Doi : 10.1016/j.ahj.2006.06.008 
Bruce A. Koplan, MD, MPH , Laurence M. Epstein, MD, Christine M. Albert, MD, William G. Stevenson, MD
Cardiac Arrhythmia Service/Division of Cardiology, Brigham and Women's Hospital, Boston, MA 

Reprint requests: Bruce A. Koplan, MD, MPH, Cardiac Arrhythmia Service/Division of Cardiology/Department of Medicine, Brigham and Women's Hospital, 75 Francis Street, Boston, MA 02115.

Résumé

Background

Athough clinical trials have expanded implantable defibrillator (ICD) indications, octogenarians have been poorly represented in these studies. Overall, survival in this subgroup is ill-defined.

Methods

Consecutive patients ≥80 years of age at ICD implant between July 1995 and September 2003 were retrospectively analyzed. Kaplan-Meier survival analysis was performed, and mortality predictors were identified. Consecutive nonelderly patients aged 60 to 70 years (60-70 group) who received ICDs over the same period were analyzed as a reference. Mortality predictors in the ≥80 group were compared to the 60-to-70 group.

Results

A total of 348 patients (age, ≥80 years [n = 107]; age, 60-70 years [n = 241]) were included. Mean follow-up time for the entire cohort was 3.3 ± 2.2 years. Other than the estimated glomerular filtration rate (eGFR) (58 ± 22 vs 66 ± 22 mL/min) in the ≥80 group versus the 60-to-70 group, no other differences in baseline characteristics were observed. Median survival was 4.2 years after implant in the ≥80 group versus 7 years in the 60-to-70 group (P < .01). Mortality predictors in the ≥80 group included ejection fraction (EF) ≤30% (hazard ratio [HR], 2.2; 95% confidence interval [CI], 1.3-4.0) and eGFR <60 mL/min (HR, 2.2; 95% CI, 1.3-3.7). In the 60-to-70 group, EF ≤30% (HR, 2.7; 95% CI, 1.6-4.5), eGFR <60 mL/min (HR, 3.4; 95% CI, 2.2-5.3), diabetes (HR, 1.8; 95% CI, 1.9-2.9), and QRS width >120 ms (HR, 2.1; 95% CI, 1.4-3.3) predicted mortality. QRS >120 ms and diabetes were not predictors in octogenarians (HR, 1.1 and 1.5, respectively; 95% CI, 0.7-1.9 and 0.8-2.7, respectively). Analysis of octogenarians subgrouped by EF ≤30% and eGFR <60 mL/min identified patients whose median survival was 6.1 years (neither predictor present; n = 28), 4.7 years (either predictor present; n = 46), and 19 months (both predictors present; n = 33) (P < .01 between groups). Survival analysis in the ≥80-year-old cohort grouped by eGFR quartile identified groups with median survival of 5.6, 4.7, 3.5 years, and 18 months, respectively, in the highest to the lowest eGFR quartile (>75, 61-75, 41-60, and <41 mL/min).

Conclusions

Median survival in octogenarian ICD recipients is greater than 4 years. In addition to baseline EF, eGFR is a strong predictor of mortality in elderly ICD candidates. These easily identifiable clinical variables may assist clinical decision making and help to provide appropriate post-ICD implant survival expectations in this elderly patient group.

Le texte complet de cet article est disponible en PDF.

Plan


© 2006  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 152 - N° 4

P. 714-719 - octobre 2006 Retour au numéro
Article précédent Article précédent
  • The effect of altering heart rate on ventricular function in patients with heart failure treated with ?-blockers
  • Simon D.R. Thackray, Justin M. Ghosh, Graham A. Wright, Klaus K.A. Witte, Nikolay P. Nikitin, Gerald C. Kaye, Andrew L. Clark, Ann Tweddel, John G.F. Cleland
| Article suivant Article suivant
  • Potential applicability and utilization of left atrial appendage occlusion devices in patients with atrial fibrillation
  • Rebecca Fountain, David R. Holmes, Patricia K. Hodgson, Krishnaswamy Chandrasekaran, Robert Van Tassel, Peter Sick

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.