S'abonner

Angioscopic evaluation of neointima coverage: Sirolimus drug-eluting stent versus bare metal stent - 18/08/11

Doi : 10.1016/j.ahj.2006.07.025 
Jota Oyabu, MD, Yasunori Ueda, MD, PhD, FACC, FESC , Nobuyuki Ogasawara, MD, Katsuki Okada, MD, Atsushi Hirayama, MD, PhD, FACC, Kazuhisa Kodama, MD, PhD, FACC
Cardiovascular Division, Osaka Police Hospital, Osaka 543-0035, Japan 

Reprint requests: Yasunori Ueda, MD, PhD, FACC, FESC, Cardiovascular Division, Osaka Police Hospital, 10-31 Kitayama-cho, Tennoji-ku, Osaka 543-0035, Japan.

Résumé

Background

The process of neointima formation after bare metal stent (BMS) implantation has been previously elucidated by angioscopic observations; however, that after drug-eluting stent (DES) implantation has not been clarified. Therefore, we compared the angioscopic appearance of neointima over DESs with that over BMSs 6 months after implantation.

Methods and Results

Patients who received an implantation of a BMS (n = 13) or a sirolimus DES (n = 24) were included in this study. Angiographic and angioscopic examinations were performed at 6 months. The color of the stented lesion (white or yellow), coverage of stent by neointima (not covered, covered by a thin layer, or buried under neointima), and thrombus at the stented lesion (presence or absence) were angioscopically evaluated. Of the 24 lesions in which a DES was implanted, 11 (46%) had a part where the stent strut had no coverage, 21 (88%) had a part where it was covered by a thin layer, and 11 (46%) had a part where it was buried under neointima. Of the 13 lesions in which a BMS was implanted, 1 (8%) lesion had a part where the stent strut had no coverage, 4 (31%) lesions had a part where it was covered by a thin layer, and 13 (100%) lesions had a part where it was buried under neointima. The prevalence of a stent buried under neointima (46% vs 100%, P = .001) was lower and that of thrombus (42% vs 8%, P = .03) was higher in DES-implanted lesions as compared with BMS-implanted lesions. The prevalence of thrombus (64% vs 17%, P = .005) was higher in the yellow area than in the white area when a DES was implanted.

Conclusion

Sirolimus DESs, as compared with BMSs, were poorly covered by neointima and were accompanied by thrombus especially when there was a yellow plaque under the stents. Thus, the thrombogenic potential in DES-implanted lesions may be sustained by the inhibition of neointima formation over thrombogenic plaques.

Le texte complet de cet article est disponible en PDF.

Plan


 Drs Oyabu and Ueda equally contributed to this article.


© 2006  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 152 - N° 6

P. 1168-1174 - décembre 2006 Retour au numéro
Article précédent Article précédent
  • Prognostic value of C-reactive protein and cardiac troponin I in primary percutaneous interventions for ST-elevation myocardial infarction
  • Patrick Ohlmann, Laurent Jaquemin, Olivier Morel, Rachid El Behlgiti, Antoine Faure, Marie-Odile Michotey, Nathalie Beranger, Gerald Roul, Francis Schneider, Pierce Bareiss, Jean-Pierre Monassier
| Article suivant Article suivant
  • Improved adherence to Swedish national guidelines for acute myocardial infarction: The Quality Improvement in Coronary Care (QUICC) study
  • Rickard Carlhed, Mats Bojestig, Lars Wallentin, Gunilla Lindström, Anette Peterson, Christina Åberg, Bertil Lindahl, for the QUICC study group

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.