S'abonner

Comparison of Feasibility and Accuracy of Transthoracic Echocardiography Versus Computed Tomography in Patients With Known Ascending Aortic Aneurysm - 17/08/11

Doi : 10.1016/j.amjcard.2006.04.043 
Gloria Tamborini, MD , Claudia Agnese Galli, MD, Anna Maltagliati, MD, Daniele Andreini, MD, Gianluca Pontone, MD, Carlo Quaglia, MD, Giovanni Ballerini, MD, Mauro Pepi, MD
Centro Cardiologico Monzino, I.R.C.C.S, Institute of Cardiology, University of Milan, Milan, Italy. 

Corresponding author: Tel: 0039-2-580021; fax: 0039-2-504667.

Résumé

Aortic valve diseases, hypertension, and connective tissue disorders may be causes of ascending aortic aneurysms. Aortic enlargement monitoring is essential for surgical timing and for operative design. In this regard, several imaging techniques may have limitations: magnetic resonance is not widespread and is expensive, computed tomography uses radiation, and transesophageal echocardiography is a semi-invasive method. The aim of this study was to analyze the feasibility of transthoracic echocardiography in the evaluation of aortic dimensions and its accuracy in comparison with multidetector computed tomography. In 44 patients with known ascending aortic aneurysms, transthoracic echocardiographic and computed tomographic measurements were obtained and compared at different levels: the annulus, sinuses of Valsalva, sinotubular junction, ascending aorta, and aortic arch. Transthoracic echocardiographic diameters were obtained in all patients, apart from the aortic arch, which was measured in 40 cases. Transthoracic echocardiographic and computed tomographic diameters correlated significantly (p <0.001), with very small SEEs: for the annulus, r = 0.846 (SEE 0.37); for the sinuses of Valsalva, r = 0.967 (SEE 0.35); for the sinotubular junction, r = 0.965 (SEE 0.33); for the ascending aorta, r = 0.976 (SEE 0.41); and for the aortic arch, r = 0.87 (SEE 0.50). In conclusion, transthoracic echocardiography is a feasible and accurate technique for the assessment and follow-up of thoracic aortic diameters in patients with ascending aortic aneurysms.

Le texte complet de cet article est disponible en PDF.

Plan


© 2006  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 98 - N° 7

P. 966-969 - octobre 2006 Retour au numéro
Article précédent Article précédent
  • Prognostic Significance of Left Atrial Size in Patients With Hypertrophic Cardiomyopathy (from the Italian Registry for Hypertrophic Cardiomyopathy)
  • Stefano Nistri, Iacopo Olivotto, Sandro Betocchi, Maria Angela Losi, Grazia Valsecchi, Bruno Pinamonti, Maria Rosa Conte, Franco Casazza, Maurizio Galderisi, Barry J. Maron, Franco Cecchi, Participating Centers
| Article suivant Article suivant
  • Differences of Lateral and Septal Mitral Annulus Velocity by Tissue Doppler Imaging in the Evaluation of Left Ventricular Diastolic Function
  • Hyeun S. Park, Sanjay D. Naik, Wilbert S. Aronow, Paul F. Visintainer, Manisha Das, John A. McClung, Robert N. Belkin

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.