S'abonner

Clinical and Angiographic Outcomes After Placement of Multiple Overlapping Drug-Eluting Stents in Diffuse Coronary Lesions - 17/08/11

Doi : 10.1016/j.amjcard.2006.05.011 
Cheol Whan Lee, MD, Kyoung-Ha Park, MD, Young-Hak Kim, MD, Myeong-Ki Hong, MD, Jae-Joong Kim, MD, PhD, Seong-Wook Park, MD, PhD, Seung-Jung Park, MD, PhD
Department of Medicine, Asan Medical Center, University of Ulsan, Seoul, Korea. 

Corresponding author: Tel: 82-2-3010-3150; fax: 82-2-486-5918.

Résumé

Multiple overlapping drug-eluting stents have increasingly been used to treat diffuse coronary disease, but the safety and efficacy of this approach remains unclear. We assayed the clinical and angiographic outcomes after placement of “full metal jacket” stents (stented length ≥60 mm) in 347 consecutive patients (352 lesions) with very long de novo coronary lesions. Mean age was 61.0 ± 10.1 years, and the mean stented length was 71.9± 13.7 mm. The procedural success rate was 97.7%. Major in-hospital complications (1death, 2 cases of acute stent thrombosis) occurred in 3 patients (0.7%). Angiographic follow-up data, obtained for 230 (234 lesions) of the 328 eligible patients (70.1%), showed that the restenosis rate was 13.7%. Multivariate analysis found that the reference artery diameter (odds ratio 0.05, 95% confidence interval [CI] 0.01 to 0.33, p = 0.002) and the use of Taxus stents (odds ratio 2.88, 95% CI 1.03 to 8.04, p = 0.043) were significant predictors of restenosis. During follow-up (16.6 ± 6.9 months), 9 deaths (6 cardiac and 3 noncardiac), 1 nonfatal myocardial infarction, and 13 target lesion revascularizations occurred. The cumulative probability of survival without major adverse cardiac events (cardiac death, Q-wave myocardial infarction, and target lesion revascularization) was 95.4 ± 1.1% and 91.4 ± 2.1% at 1 and 2 years, respectively. Left ventricular dysfunction (ejection fraction <45%) was the only predictor of stent thrombosis (hazard ratio 18.24, 95% CI 1.65 to 201.19, p = 0.018) and cardiac death/Q-wave myocardial infarction (hazard ratio 5.37, 95% CI 1.28 to 22.49, p = 0.021). In conclusion, full metal jacket drug-eluting stents may be a safe and effective method to treat diffuse coronary disease and may be a useful treatment option for complex long lesions.

Le texte complet de cet article est disponible en PDF.

Plan


 This study was supported by grants from the CardioVascular Research Foundation, Asan Institute for Life Science (Grant 2006-217), and the Korea Health 21 R&D Project, Ministry of Health & Welfare, Korea (Grant 0412-CR02-0704-0001).


© 2006  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 98 - N° 7

P. 918-922 - octobre 2006 Retour au numéro
Article précédent Article précédent
  • Impact of Percutaneous Coronary Intervention on the Levels of Interleukin-6 and C-Reactive Protein in the Coronary Circulation of Subjects With Coronary Artery Disease
  • Mahmoud M. Ramadan, Makoto Kodama, Wataru Mitsuma, Masahiro Ito, Takeshi Kashimura, Taruna Ikrar, Satoru Hirono, Yuji Okura, Yoshifusa Aizawa
| Article suivant Article suivant
  • Comparison of Mortality Rates in Statin Users Versus Nonstatin Users in a United States Veteran Population
  • Jawahar L. Mehta, Zoran Bursac, Martin Hauer-Jensen, Charlton Fort, Louis M. Fink

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.