S'abonner

Effects of a static magnetic field on wound healing: results in experimental rat colon anastomoses - 17/08/11

Doi : 10.1016/j.amjsurg.2006.01.024 
Tarik Zafer Nursal, M.D. a, , Nebil Bal, M.D. b, Ruksan Anarat, M.D. c, Tamer Colakoglu, M.D. a, Turgut Noyan, M.D. a, Gokhan Moray, M.D. d, Mehmet Haberal, M.D. d
a Department of General Surgery, Adana Teaching and Research Center, Baskent University, Dadaloglu Mah. 39. Sok. No. 6, 01250 Yuregir Adana, Turkey 
b Department of Pathology, Adana Teaching and Research Center, Baskent University, Dadaloglu Mah. 39. Sok. No. 6, 01250 Yuregir Adana, Turkey 
c Department of Biochemistry, Adana Teaching and Research Center, Baskent University, Dadaloglu Mah. 39. Sok. No. 6, 01250 Yuregir Adana, Turkey 
d Department of General Surgery, Ankara Hospital, Baskent University, 06490 Bohcelievler, Ankara, Turkey 

Corresponding author. Tel.: + 90 322 3272727, ext. 1134; fax: + 90 322 3271273.

Abstract

Background

Research has shown that pulsed electromagnetic fields (EMFs) promote wound healing in experimental colonic anastomosis; however, the effects of static EMFs in this setting have not been investigated to date.

Methods

Fifty male Wistar rats were used. Ten served as controls for mechanical strength testing, and the other 40 underwent descending colon resection and anastomosis. Twenty of these 40 animals (M group) had NeFeB magnets placed in contact with the anastomosis site (magnetic field strength at the site 390 to 420 G). The other 20 animals (sham [S] group) had nonmagnetized NeFeB bars of the same dimensions and weight implanted. Half of the animals in each group were killed and assessed for healing parameters on postoperative day 3 (M3 and S3 groups) and the other half on postoperative day 7 (M7 and S7 groups). Four types of assessment were done: gross healing, mechanical strength, hydroxyproline deposition, and histopathology.

Results

There were no differences between the M and S animals with respect to gross healing parameters. The mechanical strength was also not different between groups (23.8 ± 12.7 and 24.7 ± 9.6 mm Hg for M3 and S3, respectively; P = .863 and 91.3 ± 65.4 and 94.8 ± 55.9 mm Hg for M7 and S7, respectively; P = .902). Similarly, hydroxyproline deposition was not different between groups on postoperative day 3 or day 7. On postoperative day 3, the M group had significantly higher scores than the S group for fibroblast infiltration (2.4 ± 0.7 vs 1.4 ± 0.7, respectively; P = .008) and capillary formation (2.5 ± 0.7 vs 0.9 ± 0.4, respectively; P <.001). However, these effects were reversed and did not endure by day 7.

Conclusions

The study results suggest that static EMF has no effect on experimental colonic wound healing in the rat.

Le texte complet de cet article est disponible en PDF.

Keywords : Anastomosis, Bursting pressure, Colon, Gastrointestinal, Hydroxyproline, NeFeB magnet, Static electromagnetic field, Wound healing


Plan


© 2006  Excerpta Medica Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 192 - N° 1

P. 76-81 - juillet 2006 Retour au numéro
Article précédent Article précédent
  • Emerging endoluminal therapies for gastroesophageal reflux disease: adverse events
  • Atul K. Madan, Craig A. Ternovits, David S. Tichansky
| Article suivant Article suivant
  • The contribution of opiate analgesics to the development of infectious complications in burn patients
  • Martin G. Schwacha, Gerald McGwin, Charles B. Hutchinson, James M. Cross, Paul A. MacLennan, Loring W. Rue

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.