Endoscopic plication of massively bleeding peptic ulcer by using the Eagle Claw VII device: a feasibility study in a porcine model - 17/08/11
Hong Kong; Port Moresby, Papua New Guinea
Abstract |
Background and Objective |
We examined the efficacy of endoscopic plication when using Eagle Claw VII in a porcine bleeding ulcer model.
Animal Model Preparation |
The right gastroepiploic artery (diameter 1.5-2 mm) was isolated and was tunneled to small gastrotomies at either the lesser or greater curvature of the stomach.
Interventions |
We applied the Eagle Claw VII to achieve hemostasis.
Main Outcome Measurements |
The survival of the pigs after endoscopic plication for hemostasis, time to achieve hemostasis with Eagle Claw VII, recurrent bleeding, number of successful plication, and number of suture remained.
Results |
Endoscopic plication was performed on bleeding gastric ulcers in 6 pigs. The time to achieve hemostasis was 6 minutes 56 seconds ± 3 minutes 50 seconds. There was no complication. A total of 14 plications were performed. All animals survived for 1 week without recurrent bleeding. At the postmortem, 10 of the plication sutures remained.
Limitation |
Our model cannot simulate the chronicity of peptic ulcer.
Conclusions |
In this porcine model, the Eagle Claw VII effectively stopped bleeding from arteries 2 mm in size.
Le texte complet de cet article est disponible en PDF.Plan
The funding of this study is supported by the Endoscopy Center, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong. |