S'abonner

Accuracy of US Food and Drug Administration–cleared IgE antibody assays in the presence of anti-IgE (omalizumab) - 17/08/11

Doi : 10.1016/j.jaci.2006.01.012 
Robert G. Hamilton, PhD, DABMLI
From the Division of Allergy and Clinical Immunology, Departments of Medicine and Pathology, Johns Hopkins University School of Medicine 

Reprint requests: Robert G. Hamilton, PhD, DABMLI, Johns Hopkins Asthma and Allergy Center, Room 1A20, 5501 Hopkins Bayview Circle, Baltimore, MD 21224.

Baltimore, Md

Abstract

Background

Although serological IgE measurements can aid in efficacy assessment of patients with asthma on omalizumab (Xolair [Genentech, Inc., South San Francisco, Calif]; humanized IgG1 antihuman IgE Fc), its effect on clinically used IgE assay performance is unknown.

Objective

This study investigated the hypothesis that IgE:IgG–anti-IgE immune complex formation after omalizumab administration diminishes accuracy and increases variability of IgE assays performed in diagnostic immunology laboratories.

Methods

Plasma from 4 atopic adults was incubated with omalizumab (50 or 200 molar excess to IgE) or buffer. Paired specimens were sent masked to 159 clinical laboratories in the College of American Pathologists Diagnostic Allergy Proficiency Survey (cycles SE-C-2003, SE-A-2005). Inhibitory effects produced by omalizumab on accuracy and reproducibility of US Food and Drug Administration (FDA)–cleared total and allergen-specific IgE assays were computed by using national proficiency survey data.

Results

Total serum IgE levels measured in the 2 ImmunoCAP assays were minimally reduced (2.4-9.0%) by the presence of omalizumab, whereas 5 other assays showed marked reductions from 12.5% to 67.2% (P < .001) that increased in proportion to total serum IgE levels. The degree of interference was not large enough to produce detectable misclassification of IgE antibody results (positive to negative) in 4 multiallergen screening assays. Of 11 FDA-cleared IgE antibody assays, only 3 (ImmunoCAP, UniCAP, Immulite-2000) generated quantitative IU/mL results that could be assessed for interference. Omalizumab produced 0.8% to 27.8% reduction in allergen-specific IgE levels across 8 allergen specificities.

Conclusion

Although as much as 62% loss in accuracy was observed in FDA-cleared human IgE assays, the ImmunoCAP system was sufficiently robust to provide accurate and reproducible total and allergen-specific IgE antibody results in a clinical setting where therapeutic levels of omalizumab are present in serum.

Clinical implications

Accurate monitoring of total and allergen-specific IgE, together with free IgE levels, in serum from patients on omalizumab may help optimize dosing and maximize the efficacy of Xolair therapy.

Le texte complet de cet article est disponible en PDF.

Key words : Human, IgE, IgE antibody, omalizumab (Xolair), human IgG1 anti-IgE, human IgG antihuman IgE autoantibodies, College of American Pathologists proficiency survey, immunoenzymetric assay, ⍺-FcεR1

Abbreviations used : CAP, CV, FDA, SE


Plan


 Supported by internal funds from the Johns Hopkins University School of Medicine.
Disclosure of potential conflict of interest: R. G. Hamilton received grants/research support from Johns Hopkins University Internal Funds.


© 2006  American Academy of Allergy, Asthma and Immunology. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 117 - N° 4

P. 759-766 - avril 2006 Retour au numéro
Article précédent Article précédent
  • Primary immunodeficiency or not? Making the correct diagnosis
  • Rebecca H. Buckley
| Article suivant Article suivant
  • Bronchial challenges in athletes applying to inhale a β2-agonist at the 2004 Summer Olympics
  • Sandra D. Anderson, Malcolm Sue-Chu, Clare P. Perry, Christina Gratziou, Pascale Kippelen, Don C. McKenzie, Ken C. Beck, Ken D. Fitch

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.