S'abonner

Evaluation of coronary artery bypass grafts and native coronary arteries using 64-slice multidetector computed tomography - 16/08/11

Doi : 10.1016/j.ahj.2007.04.054 
Yoshinobu Onuma, MD a, Kengo Tanabe, MD, PhD a, , Ruri Chihara, MD a, Hirosada Yamamoto, MD a, Yujiro Miura, MD b, Ikutaro Kigawa, MD b, Sachito Fukuda, MD b, Takeshi Miyairi, MD, PhD b, Hiroyoshi Nakajima, MD, PhD b, Kazuhiro Hara, MD a
a Division of Cardiology, Mitsui Memorial Hospital, Tokyo, Japan 
b Division of Cardiovascular Surgery, Mitsui Memorial Hospital, Tokyo, Japan 

Reprint requests: Kengo Tanabe, MD, PhD, Division of Cardiology, Mitsui Memorial Hospital, 1, Kanda-Izumi-cho, Chiyoda-ku, Tokyo, Japan.

Résumé

Background

The conventional use of 16-slice multidetector computed tomography (MDCT) remains somewhat limited for evaluating stenoses in vein graft distal anastomotic sites and in coronary arteries. We investigated the diagnostic accuracy of 64-slice MDCT for assessment of both grafts and coronary arteries in patients with coronary artery bypass grafts.

Method

The study group included 54 consecutive patients. One patient had to be excluded from the study because of arrhythmia. The remaining 53 patients with coronary artery bypass grafts underwent both 64-slice MDCT angiography and invasive coronary angiography. The MDCTs were analyzed for presence of significant stenosis (>50%) or occlusion in grafts and coronary arteries. The results were compared with those of invasive coronary angiography.

Results

Overall, 138 of 146 (94.5%) grafts including distal anastomoses were evaluable with MDCT. Evaluability of arterial grafts, venous grafts, distal runoff arteries, and nongrafted arteries was 90.3%, 98.6%, 84.0%, and 97.3%, respectively. After censoring nonevaluable grafts or arteries and considering them to be positive, the sensitivity to detect significant stenosis or occlusion in arterial grafts was 100% and specificity was 91.4%. In venous graft, sensitivity was 100% and specificity was 98.1%. In distal runoff arteries, sensitivity to detect significant stenoses was 83.3% and specificity was 80.2%. In nongrafted arteries, sensitivity was 100% and specificity was 87.5%.

Conclusions

Sixty-four-slice MDCT showed improved ability to assess bypass grafts and coronary arteries. However, there were still difficulties in assessment of distal runoff arteries in which relatively low diagnostic accuracy was observed that might limit clinical implementation of MDCT.

Le texte complet de cet article est disponible en PDF.

Plan


© 2007  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 154 - N° 3

P. 519-526 - septembre 2007 Retour au numéro
Article précédent Article précédent
  • Left ventricular opacification for the diagnosis of coronary artery disease with stress echocardiography: An angiographic study of incremental benefit and cost-effectiveness
  • Stuart Moir, Leslee Shaw, Brian Haluska, Carly Jenkins, Thomas H. Marwick
| Article suivant Article suivant
  • Echocardiographic characteristics of professional tennis players at the Roland Garros French open
  • Nicolas Mansencal, Dany-Michel Marcadet, Fabrice Martin, Bernard Montalvan, Olivier Dubourg

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.