Résumé

Background

Open surgical valvotomy and transcatheter balloon valvuloplasty are recognised treatments for neonatal critical aortic stenosis.

Methods

A retrospective analysis was undertaken of all newborns with critical aortic valve stenosis between 1990 and 2000 presenting to a tertiary centre and who required intervention. The initial catheter and surgical intervention was generally based on the preference of the attending cardiologist and the anatomy of the aortic valve and in consultation with the cardiothoracic surgeon. The two groups were therefore not strictly comparable. Twelve were subjected to balloon valvuloplasty and thirteen to surgical valvotomy at a median age of 11 days (2–42 days) and 3.5 days (1–19 days) respectively. There was no significant difference in the timing of the procedure, weight of the infant, aortic annulus or left ventricular dimensions in either group.

Results

There was one unrelated hospital death in the balloon group compared to two in the surgical group both of whom had endocardial fibroelastosis. Mild to moderate aortic regurgitation was seen after both procedures. Four patients in the balloon valvuloplasty group, developed femoral artery thrombosis and two had cardiac perforation that resolved with non operative management. The mean Doppler gradient was reduced from 44±14mmHg to 13.4±5mmHg (p<0.01) in the valvuloplasty group compared to a reduction from 42±15mmHg to 27±8mmHg (p<0.05) in the surgical group. Five patients in the balloon group required re-intervention within 3 weeks to 21 months after the initial procedure. Two patients in the surgical group required a pulmonary autograft and Konno Procedure 3 and 5 years following surgical valvotomy.

Conclusion

Both aortic valvulopasty and valvotomy offered effective short and medium term palliation. Balloon valvuloplasty patients had a higher re-intervention rate but shorter hospital and intensive care stay, reduced immediate morbidity and were associated with less severe aortic regurgitation.

Le texte complet de cet article est disponible en PDF.

Keywords : Aortic Valve Stenosis, Valvuloplasty, Valvotomy, Newborn


Plan


 Presented in part at the World Congress of Paediatric Cardiology and Cardiac Surgery, Toronto, May 2001.


© 2005  Australasian Society of Cardiac and Thoracic Surgeons and the Cardiac Society of Australia and New Zealand. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 15 - N° 1

P. 18-23 - février 2006 Retour au numéro
Article précédent Article précédent
  • Transcatheter Closure of Muscular Ventricular Septal Defect Using the Amplatzer Devices
  • Mulyadi M. Djer, Haifa Abdul Latiff, Mazeni Alwi, Hasri Samion, Geetha Kandavello
| Article suivant Article suivant
  • Pulmonary Parasitosis: Applied Clinical and Therapeutic Issues
  • Sameh Ibrahim Sersar, Hala Ahmed Elnahas, Abdel Basset Mohammed Saleh, Sherif Abdou Moussa, Wael A. Abdel Ghafar

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.