S'abonner

Accuracy of 64-Slice Computed Tomography for the Preoperative Detection of Coronary Artery Disease in Patients With Chronic Aortic Regurgitation - 16/08/11

Doi : 10.1016/j.amjcard.2007.03.087 
Hans Scheffel, MD a, Sebastian Leschka, MD a, André Plass, MD b, Robert Vachenauer, MD b, Oliver Gaemperli, MD c, Elisabeth Garzoli, MD a, Michele Genoni, MD b, Borut Marincek, MD a, Philipp Kaufmann, MD c, d, Hatem Alkadhi, MD a,
a Institute of Diagnostic Radiology, University Hospital Zurich, Zurich, Switzerland 
b Clinic for Cardiovascular Surgery, University Hospital Zurich, Zurich, Switzerland 
c Cardiovascular Center, University Hospital Zurich, Zurich, Switzerland 
d Center for Integrative Human Physiology, University of Zurich, Zurich, Switzerland. 

Corresponding author: Tel: 41-44-255-3662; fax: 41-44-255-4443.

Résumé

We studied the diagnostic accuracy of 64-slice computed tomography for the diagnosis of significant coronary artery disease (CAD) compared with conventional coronary angiography (CA) in patients with chronic aortic regurgitation (AR) referred for elective aortic valve surgery. Fifty consecutive patients with chronic AR (38 men, mean age 54 ± 14 years) scheduled for valve surgery underwent 64-slice computed tomographic (CT) coronary angiography and CA. Significant stenosis was defined as a luminal diameter decrease >50%. Mean heart rate during CT scanning was 65.5 ± 7.4 beats/min. Mean Agatston score was 136 ± 278 (range 0 to 1207); prevalence of significant CAD in the study population was 26% (13 of 50 patients). Thirteen of 742 segments (1.8%) in 3 patients were considered nondiagnostic with computed tomography because of motion artifacts (n = 9) or calcium (n = 4). In a patient-based analysis taking nonevaluative segments as falsely positive, sensitivity, specificity, and positive and negative predictive values of computed tomography were 100%, 95%, 87%, and 100%, respectively. Preoperative CA could have been avoided in 70% of patients (35 of 50), CA would have been performed to confirm the CT diagnosis in 26% (13 of 50), and unnecessary CA would have been performed in 4% (2 of 50) on the basis of false-positive CT ratings. In conclusion, 64-slice CT coronary angiography provides high diagnostic accuracy for diagnosing significant CAD in patients with chronic AR and may be used as a filter test before valve surgery to decide whether CA should be performed.

Le texte complet de cet article est disponible en PDF.

Plan


 This research was supported by the National Center of Competence in Research, Computer Aided and Image Guided Medical Interventions of the Swiss National Science Foundation, Zurich, Switzerland.


© 2007  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 100 - N° 4

P. 701-706 - août 2007 Retour au numéro
Article précédent Article précédent
  • Validation of the Seattle Heart Failure Model in a Community-Based Heart Failure Population and Enhancement by Adding B-Type Natriuretic Peptide
  • Heidi T. May, Benjamin D. Horne, Wayne C. Levy, Abdallah G. Kfoury, Kismet D. Rasmusson, David T. Linker, Dariush Mozaffarian, Jeffrey L. Anderson, Dale G. Renlund
| Article suivant Article suivant
  • Effect of Primary Mitral Regurgitation on Left Ventricular Synchrony
  • Thomas S. Denney, Hosakote M. Nagaraj, Steven G. Lloyd, Inmaculada Aban, Cecilia Corros, Frank Seghatol-Eslami, David C. McGiffin, Louis J. Dell’Italia, Himanshu Gupta

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.