S'abonner

Frequency of Stent Fracture as a Cause of Coronary Restenosis After Sirolimus-Eluting Stent Implantation - 16/08/11

Doi : 10.1016/j.amjcard.2007.03.073 
Sang-Hee Lee, MD, Jong-Seon Park, MD, PhD , Dong-Gu Shin, MD, PhD, Young-Jo Kim, MD, PhD, Gue-Ru Hong, MD, PhD, Woong Kim, MD, Bong-Sup Shim, MD
Division of Cardiology, Department of Internal Medicine, Yeung-nam University Hospital, Daegu, Korea. 

Corresponding author: Tel.: 82-53-620-3847; fax: 82-53-654-8386.

Résumé

Stent fracture (SF) was suggested as a cause of restenosis after sirolimus-eluting stent (SES) implantation. This study was performed to evaluate the incidence and characteristics of SF to determine its contribution to restenosis in patients with in-stent restenosis (ISR) after SES implantation. From May 2003 to February 2006, SESs were used for percutaneous coronary intervention in 868 patients with 1,109 coronary narrowings. Follow-up coronary angiography was performed in 366 patients (42%), and 26 ISR lesions were observed. These patients were enrolled in this study. SF was divided into 3 types as avulsion, collapse, and partial based on the findings of fluoroscopy, coronary angiography, and intravascular ultrasound study. Of 26 patients with ISR lesions, SF was identified in 10. SF types were avulsion (5 patients), collapse (2 patients), and partial (3 patients). SF was identified at the midshaft (7 patients) and overlap sites (3 patients) of stents. SF was not observed in the 30 patients with ISR after bare-metal Bx Velocity stent implantation. Four patients with SF were treated with paclitaxel-eluting stents. In conclusion, SF is 1 of the leading causes of ISR after SES implantation. Careful fluoroscopic examination is necessary at the time of follow-up angiography to identify this problem.

Le texte complet de cet article est disponible en PDF.

Plan


© 2007  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 100 - N° 4

P. 627-630 - août 2007 Retour au numéro
Article précédent Article précédent
  • Meta-Analysis of Angiographic Versus Intravascular Ultrasound Parameters of Drug-Eluting Stent Efficacy (from TAXUS IV, V, and VI)
  • Esteban Escolar, Gary S. Mintz, Jeffrey Popma, Aleksandra Michalek, Sang Wook Kim, Lazar Mandinov, Joerg Koglin, Gregg Stone, Stephen G. Ellis, Eberhard Grube, Keith D. Dawkins, Neil J. Weissman
| Article suivant Article suivant
  • Usefulness of Preprocedural N-Terminal Pro-Brain Natriuretic Peptide in Predicting Angiographic No-Reflow Phenomenon During Stent Implantation in Patients With ST-Segment Elevation Acute Myocardial Infarction
  • Seo Na Hong, Youngkeun Ahn, Sun Ho Hwang, Nam Sik Yoon, Sang Rok Lee, Jae Youn Moon, Kye Hun Kim, Young Joon Hong, Hyung Wook Park, Ju Han Kim, Myung Ho Jeong, Jeong Gwan Cho, Jong Chun Park, Jung Chaee Kang

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.