S'abonner

Usefulness of Microvolt T-Wave Alternans on Predicting Outcome in Patients With Ischemic Cardiomyopathy With and Without Defibrillators - 16/08/11

Doi : 10.1016/j.amjcard.2007.03.069 
Theodore Chow, MD a, , Sayed Saghir, MD a, Cheryl Bartone, BS a, Megan Goebel, BS a, Julia Schneider a, Terri Booth, RN a, Paul S. Chan, MD, MSc b
a The Lindner Clinical Trial Center, Christ Hospital and Ohio Heart and Vascular Center, Cincinnati, Ohio 
b VA Health Services Research and Development and University of Michigan Medical School, Ann Arbor, Michigan. 

Corresponding author: Tel.: 734-936-8214; fax: 734-761-2939.

Résumé

Microvolt T-wave alternans (MTWA) was proposed as an effective tool to identify high-risk patients with ischemic cardiomyopathy. However, previous studies suggested that the prognostic utility of MTWA may be limited to only patients with normal QRS duration. It therefore was assessed whether MTWA and QRS duration >120 ms independently predict mortality in patients with ischemic cardiomyopathy and whether the prognostic utility of MTWA differs by QRS duration. A total of 768 consecutive patients with ischemic cardiomyopathy (left ventricular ejection fraction ≤35%) and no history of ventricular arrhythmia were enrolled, of whom 514 (67%) screened MTWA non-negative (positive or indeterminate) and 223 (29%) had a QRS >120 ms on resting electrocardiogram. After multivariable adjustment, a non-negative MTWA test result was associated with a significantly higher risk for all-cause mortality in patients without an implantable cardioverter-defibrillator (ICD) (hazard ratio [HR] 2.27, 95% confidence interval [CI] 1.22 to 4.24, p = 0.01) and for all-cause mortality and appropriate ICD shocks in patients with an ICD (HR 2.42, 95% CI 1.07 to 5.41, p = 0.04). In contrast, a QRS >120 ms was not associated with all-cause mortality and ICD shocks in patients without (HR 0.96, 95% CI 0.52 to 1.75, p = 0.88) or with an ICD (HR 1.25, 95% CI 0.76 to 2.08, p = 0.40). No significant interaction was found between MTWA and QRS >120 ms (non-ICD p = 0.19, ICD p = 0.73). In conclusion, MTWA, but not QRS duration, predicted mortality outcomes in patients with ischemic cardiomyopathy. Moreover, the prognostic utility of MTWA did not appear to differ by QRS duration.

Le texte complet de cet article est disponible en PDF.

Plan


 This work was supported in part by Medtronic, Minneapolis, Minnesota. Dr. Chan is supported by a Cardiovascular Multidisciplinary Research Training Grant from the National Institutes of Health, Bethesda, Maryland, and by the Ruth L. Kirchstein Research Service Award, Bethesda, Maryland. None of the sponsors had any involvement in the design, collection, management, or analysis of the study or in manuscript preparation.


© 2007  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 100 - N° 4

P. 598-604 - août 2007 Retour au numéro
Article précédent Article précédent
  • Peripheral-Blood Dendritic Cells in Men With Coronary Heart Disease
  • Hongyu Shi, Junbo Ge, Weiyi Fang, Kang Yao, Aijun Sun, Rongchong Huang, Qingzhe Jia, Keqiang Wang, Yunzeng Zou, Xuetao Cao
| Article suivant Article suivant
  • Comparison of the Prognostic Value of the Stress-Recovery Index Versus Standard Electrocardiographic Criteria in Patients With a Negative Exercise Electrocardiogram
  • Riccardo Bigi, Lauro Cortigiani, Dario Gregori, Cesare Fiorentini

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.