S'abonner

Accurate quantification of pulmonary artery diameter in patients with cyanotic congenital heart disease using multidetector-row computed tomography - 15/08/11

Doi : 10.1016/j.ahj.2007.06.004 
Yasunobu Hayabuchi, MD a, , Kazuhiro Mori, MD a, Tetsuya Kitagawa, MD b, Miki Inoue, MD a, Shoji Kagami, MD a
a Department of Pediatrics, University of Tokushima, Tokushima, Japan 
b Department of Cardiovascular Surgery, University of Tokushima, Tokushima, Japan 

Reprint requests: Yasunobu Hayabuchi, MD, Department of Pediatrics, University of Tokushima, Kuramoto-cho-3, Tokushima 770-8305, Japan.

Résumé

Background

The purpose of this study is to assess the feasibility of multidetector-row computed tomography (MDCT) for the quantitative evaluation of pulmonary artery morphology in children with congenital heart disease that is associated with reduced pulmonary blood flow.

Methods

Quantification of measurements at the pulmonary artery annulus and right and left pulmonary arteries, and detection of stenoses exceeding 30% diameter reduction were evaluated independently on MDCT and conventional invasive angiography in 56 MDCT scans of 44 children. The diameters of the right and left pulmonary arteries were measured just proximal to the first branch and at the site of maximum stenosis.

Results

There was an excellent correlation between MDCT and conventional pulmonary angiography in quantifying the diameter of the right and left pulmonary arteries (R2 = 0.85 and 0.82, respectively), although a systematic overestimation was observed on MDCT (bias 0.38 ± 0.49 and 0.28 ± 0.54 mm, respectively). The pulmonary artery annulus diameter on MDCT scans moderately correlated with the measurement on conventional angiograms (R2 = 0.48). Multidetector-row computed tomography correctly detected 15 of 16 pulmonary artery stenotic lesions that were detected on invasive angiography. There was an excellent correlation between MDCT and conventional angiograms with respect to evaluation of stenotic sites (R2 = 0.82).

Conclusions

Our findings showed a strong correlation of vessel diameter measurements between MDCT and invasive pulmonary angiography. This study demonstrates the feasibility of MDCT in assessing pulmonary artery size and morphology.

Le texte complet de cet article est disponible en PDF.

Plan


© 2007  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 154 - N° 4

P. 783-788 - octobre 2007 Retour au numéro
Article précédent Article précédent
  • Long-term effect of bosentan in adults versus children with pulmonary arterial hypertension associated with systemic-to-pulmonary shunt: Does the beneficial effect persist?
  • Rosa Laura E. van Loon, Elke S. Hoendermis, Marielle G.J. Duffels, Anton Vonk-Noordegraaf, Barbara J.M. Mulder, Hans L. Hillege, Rolf M.F. Berger
| Article suivant Article suivant
  • Evaluation of cardiac function of the fetus by inferior vena cava diameter pulse waveform
  • Akira Mori, Noa Uchida, Yoko Ishiguro, Togo Atsuko, Mitsuzuka Kanako, Mikami Mikio

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.