Background

The benefits of intra-aortic balloon pumping (IABP) usage reportedly occur through systolic unloading of the left ventricle and the augmentation of diastolic coronary flow. The aim of this study was to assess the change in intracoronary pressure distal to the coronary stenosis after the IABP by using an intracoronary pressure wire.

Methods

Hemodynamic variables and intracoronary pressure data were measured in 16 patients requiring IABP for clinical indication (11 vessels with coronary stenosis and 5 normal vessels were enrolled). Coronary pressure was measured directly in each vessel with and without IABP support.

Results

The diastolic aortic pressure during IABP increased compared with that without the IABP (97.9 ± 11.7 vs 80.3 ± 10.7 mm Hg, P < .01). The systolic aortic and intracoronary pressure during the IABP decreased (aortic pressure: 83.8 ± 10.4 vs 95.9 ± 11.3 mm Hg, P < .01, intracoronary pressure: 67.6 ± 16.5 vs 76.2 ± 20.4 mm Hg, P < .01). The diastolic distal coronary pressure (Pd) increased during the IABP in healthy coronary arteries (87.3 ± 4.8 vs 72.1 ± 10.3 mm Hg, P < .05). However, Pd in stenotic coronary arteries with the IABP did not increase statistically compared with those without the IABP (44.0 ± 21.3 vs 42.8 ± 17.9 mm Hg). There was a significant correlation between the change in Pd after IABP insertion and percent diameter stenosis calculated by quantitative coronary angiography (r2 = 0.51, P < .001).

Conclusions

In the presence of a critical coronary stenosis, the IABP does not increase the diastolic coronary pressure distal to the stenosis. Thus, the major effect of IABP on high-risk patients with severe coronary stenosis may relate to the reduction of oxygen demand by systolic unloading more than diastolic augmentation of the coronary flow.

Le texte complet de cet article est disponible en PDF.

Plan


© 2007  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 154 - N° 4

P. 725-731 - octobre 2007 Retour au numéro
Article précédent Article précédent
  • A 6-month randomized pilot study of black tea and cardiovascular risk factors
  • Kenneth J. Mukamal, Kristen MacDermott, Joe A. Vinson, Noriko Oyama, Warren J. Manning, Murray A. Mittleman
| Article suivant Article suivant
  • Dual antiplatelet agent failure: A new syndrome or clinical nonentity?
  • Geoffrey D. Barnes, Jin Li, Eva Kline-Rogers, Ameeth Vedre, David F. Armstrong, James B. Froehlich, Kim A. Eagle, Hitinder S. Gurm

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.