The use of ultrasound to identify pertinent landmarks for lumbar puncture - 15/08/11

Doi : 10.1016/j.ajem.2006.07.010 
Kirk A. Stiffler, MD , Sharhabeel Jwayyed, MD, Scott T. Wilber, MD, Angela Robinson, DO
Department of Emergency Medicine, Summa Health System, Akron, OH, USA 
Northeastern Ohio Universities College of Medicine, Rootstown, OH, USA 

Corresponding author. Emergency Medicine Research Center, Summa Health System, Akron City Hospital, PO Box 2090, Akron, OH 44309-2090, USA. Tel.: +1 330 375 7530; fax: +1 330 375 7564.

Abstract

Objective

This study was conducted to assess the ultrasound's (US's) ability to identify pertinent landmarks for lumbar puncture (LP) in patients of various body mass indices (BMIs) and establish spatial relationships of pertinent LP landmarks across BMIs.

Methods

In this institutional review board–approved cross-sectional study, we calculated the BMIs of eligible patients and then categorized them as normal (BMI ≤24.9), overweight (BMI 24.9-30), or obese (BMI ≥30). We recorded the difficulty in palpating traditional LP landmarks. Identification and measurement of the spatial relationships of the sacrum; spinous processes of lumbar vertebrae L3, L4, and L5; ligamentum flavum; and the spinal canal by US was attempted.

Results

Successful identification of pertinent structures (L4-L5 spinous processes and the spinal canal) occurred in 100% of patients with normal BMI, 95% of those who were overweight, and 74% of those who were obese (P = .011). Difficulty in palpating landmarks was noted in 5% of patients with normal BMI, 33% of those who were overweight, and 68% of those who were obese (P < .0001). In subjects with difficult-to-palpate landmarks, US identified pertinent structures in 16 of 21 (76%; 95% confidence interval, 53-92). The average distance from skin to ligamentum flavum was 44 mm in those with normal BMI, 51 mm in those who were overweight, and 64 mm in those who were obese (P < .00001); measurements between spinous processes did not vary by BMI. Overall, there was a moderate correlation (0.62) between BMI and the distance from skin to ligamentum flavum.

Conclusion

The usefulness of US in identifying structures for LP is inversely related to BMI. Even with this limitation, US is still able to identify obese patients' pertinent landmarks almost 75% of the time. In addition, US may be helpful in identifying pertinent structures for LP in those patients with difficult-to-palpate landmarks. In patients who were obese with structures not palpable by hand or identifiable by US, other modalities should be considered.

Le texte complet de cet article est disponible en PDF.

Plan


 Presented as poster at the American College of Emergency Physicians National Scientific Assembly, Washington, DC, on September 26, 2005.


© 2007  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 25 - N° 3

P. 331-334 - mars 2007 Retour au numéro
Article précédent Article précédent
  • Application of clinical criteria for ordering radiographs to detect cervical spine fractures
  • Ronald M. Moscati, E. Brooke Lerner, Jennifer L. Pugh
| Article suivant Article suivant
  • Decrease in NTproBNP plasma levels indicates clinical improvement of acute decompensated heart failure
  • Salvatore Di Somma, Laura Magrini, Marinella Mazzone, Raffaella De Leva, Fabio Tabacco, Rossella Marino, Veronica Talucci, Enrico Ferri, Paola Forte, Patrizia Cardelli, Nicola Gentiloni, Valerio Pittoni

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.