S'abonner

Hemoperfusion using dual pulsatile pump in paraquat poisoning - 15/08/11

Doi : 10.1016/j.ajem.2007.09.022 
Gil J. Suh, MD a, Christopher C. Lee, MD b, , Ik J. Jo, MD c, Sang D. Shin, MD a, Jung C. Lee, MD d, Byung G. Min, MD d, Adam J. Singer, MD b
a Department of Emergency Medicine, Seoul National University College of Medicine, Seoul, Korea 
b Department of Emergency Medicine, Center for International Emergency Medicine, Stony Brook University Medical Center, Stony Brook, NY, USA 
c Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University, Seoul, Korea 
d Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul, Korea 

Corresponding author. Department of Emergency Medicine, Center for International Emergency Medicine, Stony Brook University Medical Center, School of Medicine, Stony Brook, NY 11794, USA. Tel.: +1 631 444 3880; fax: +1 631 444 3919.

Abstract

Introduction

Hemoperfusion is an effective method for removing paraquat from the body. However, the need for special equipment and personnel to perform hemoperfusion limits its applicability in the emergency department. A portable, user-friendly extracorporeal life support system (Twin Pulse Life Support [T-PLS]) capable of producing dual pulsatile flow by an electromechanical blood pump has recently been developed. We compared the effects of hemoperfusion using traditional and dual-pulsatile pumps in a paraquat-intoxicated canine model. We hypothesized that T-PLS would be as effective as nonpulsatile hemoperfusion in reducing plasma and tissue paraquat levels.

Methods

Twelve adult male mongrel dogs were randomly assigned to hemoperfusion using a standard nonpulsatile pump (n = 6) or the T-PLS (n = 6). Paraquat intoxication was induced by intramuscular injection of paraquat (30 mg/kg). One hour after paraquat administration, hemoperfusion was performed for 4 hours at a flow rate of 125 mL/min. Periodic hemodynamic, chemical, and hematologic parameters as well as paraquat blood levels were obtained before and during the experiment. All animals were euthanized after completing 4 hours of hemoperfusion, and tissue levels of paraquat were determined.

Results

During hemoperfusion, hemodynamic parameters including aortic blood pressure, heart rate, rectal temperature, and Sao2 showed no significant difference between the T-PLS group and the nonpulsatile pump groups. Chemical and hematologic parameters such as serum electrolytes, platelet level, creatinine concentration, the ratio of blood urea nitrogen (BUN) to creatinine, alanine aminotransferase/aspartate aminotransferase (ALS/AST) levels, and plasma hemoglobin concentration as an indicator of hemolysis also showed no between-group differences. Plasma paraquat concentrations and lung and kidney tissue paraquat concentrations were also similar in both groups.

Conclusions

In this experimental canine study, T-PLS was as effective as traditional nonpulsatile hemoperfusion in reducing plasma and tissues paraquat levels. There were also no differences in hemodynamic, chemical, and hematologic parameters between the groups. Hemoperfusion using T-PLS may play a role as an alternative method for treating patients with paraquat poisoning.

Le texte complet de cet article est disponible en PDF.

Plan


© 2008  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 26 - N° 6

P. 641-648 - juillet 2008 Retour au numéro
Article précédent Article précédent
  • Information for Authors
| Article suivant Article suivant
  • Utstein style study of cardiopulmonary bypass after cardiac arrest
  • Katsutoshi Tanno, Yasushi Itoh, Yoshihiro Takeyama, Satoshi Nara, Kazuhisa Mori, Yasufumi Asai

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.