S'abonner

Comparison of Interpretations of Valve Structure Between Cardiac Surgeon and Cardiac Pathologist Among Adults Having Isolated Aortic Valve Replacement for Aortic Valve Stenosis (± Aortic Regurgitation) - 13/08/11

Doi : 10.1016/j.amjcard.2008.12.044 
William Clifford Roberts, MD a, b, c, , Travis James Vowels a, Jong Mi Ko, BA a
a Baylor Heart and Vascular Institute, Baylor University Medical Center, Dallas, Texas 
b Department of Pathology, Baylor University Medical Center, Dallas, Texas 
c Department of Internal Medicine, Division of Cardiology, Baylor University Medical Center, Dallas, Texas 

Corresponding author: Tel: 214-820-7911; fax: 214-820-7533

Résumé

Most studies concerning aortic valve structure in patients having aortic valve replacement have utilized the valve structure (unicuspid, bicuspid, tricuspid) as that called by the cardiac surgeon performing the operation. We determined valve structure of 744 operatively excised stenotic aortic valves submitted to the surgical pathology laboratory of a single hospital over a 6-year period and then compared valve structure determined by a single cardiac pathologist (WCR) with that recorded in the operative report dictated by the operating surgeon. Compared with that determined from examination of the operatively excised valve by the cardiac pathologist, valve structure determined at operation was congruous in 59% (440 of 744 patients), incongruous in 20% (152 of 744), of uncertain structure in 1% (9 of 744), and not mentioned in 19% (143 of 744). Valve structure was virtually always congruous (278 of 280 cases, 99%) in patients with 3-cuspid valves, less so with bicuspid valves (156 of 280, 56%), and infrequently so with unicuspid valves (6 of 41, 15%). In conclusion, in patients having isolated aortic valve replacement for aortic valve stenosis, the structure of the valve by the operating surgeon was similar (99%) to that described by 1 of us (WCR) when a 3-cuspid aortic valve was excised, but less so when a congenitally unicuspid (15%) or bicuspid (56%) valve was excised.

Le texte complet de cet article est disponible en PDF.

Plan


© 2009  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 103 - N° 8

P. 1139-1145 - avril 2009 Retour au numéro
Article précédent Article précédent
  • Effects of Darbepoetin Alfa on Plasma Mediators of Oxidative and Nitrosative Stress in Anemic Patients With Chronic Heart Failure Secondary to Ischemic or Idiopathic Dilated Cardiomyopathy
  • John T. Parissis, Kallirrhoe Kourea, Ioanna Andreadou, Ignatios Ikonomidis, Sophia Markantonis, Konstadinos Ioannidis, Ioannis Paraskevaidis, Efstathios Iliodromitis, Gerasimos Filippatos, Dimitrios Th. Kremastinos
| Article suivant Article suivant
  • Characteristics in Phenotypic Manifestations of Genetically Proved Marfan Syndrome in a Japanese Population
  • Koichi Akutsu, Hiroko Morisaki, Satoshi Takeshita, Hitoshi Ogino, Masahiro Higashi, Toshiya Okajima, Tsuyoshi Yoshimuta, Yoshiaki Tsutsumi, Hiroshi Nonogi, Takayuki Morisaki

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.