S'abonner

Absorbable ligation loops for flexible endoscopy: a necessary tool for natural orifice transluminal endoscopic surgery - 11/08/11

Doi : 10.1016/j.gie.2010.11.052 
Markus B. Schoenberg , Philipp Ströbel, MD, PhD, Daniel von Renteln, MD, Axel Eickhoff, MD, Georg F. Kähler, MD
 Current affiliations: Central Interdisciplinary Endoscopy (M.B.S., G.K.), University Hospital Complex Mannheim; Institute of Pathology (P.S.), Medical Faculty Mannheim, University of Heidelberg, Mannheim; Department for Interdisciplinary Endoscopy (D.v.R., A.E.), University Hospital Complex Hamburg-Eppendorf, Hamburg, Germany 

Reprint requests: Markus Schoenberg, University Hospital Complex Mannheim, Central Interdisciplinary Endoscopy, Theodor-Kutzer-Ufer 1-3, Mannheim, DE 68167

Résumé

Background

One of the main challenges of natural orifice transluminal endoscopic surgery (NOTES) remains the development of safe and reliable tools. In this study, we introduce the first absorbable ligatures specifically designed for NOTES.

Objective

To determine the feasibility of a new absorbable ligation loop (NOTES loop) and to compare this new type of suture with the nonabsorbable loop (Endoloop) most commonly used until now.

Design

Prospective, comparative animal trial/survival animal study (observation period 21 days) with subsequent histopathological assessment (blinded observer design).

Setting

Veterinarian center.

Subjects

This study used 12 female domestic piglets.

Intervention

Every pig underwent two transgastric uterine horn ligations, one with an absorbable loop and one with a nonabsorbable loop. Additional uterine horn resections on both sides were done on 6 pigs.

Main Outcome Measurements

Intervention success, loop reliability, foreign-body reaction, extent of inflammatory response (μm).

Results

Transgastric flexible intra-abdominal ligation of the uterine horns was performed safely with both loops in all cases. During a 3-week observation period, 11 of 11 NOTES loops and 10 of 11 Endoloops were reliable. Microscopically, foreign-body reaction was minimal around both sutures (P = .303). The overall inflammatory response was larger around the Endoloops (P = .046). Uterine horn resection had an influence on the extent of inflammation.

Limitations

Animal study.

Conclusion

Ligation was feasible with both loops. The absorbable loops were reliable during a 3-week observation period and can be recommended for use during NOTES appendectomies.

Le texte complet de cet article est disponible en PDF.

Abbreviations : NL, NOTES, USP


Plan


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.


© 2011  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 73 - N° 4

P. 791-797 - avril 2011 Retour au numéro
Article précédent Article précédent
  • A prospective, randomized trial of esophageal submucosal tunnel closure with a stent versus no closure to secure a transesophageal natural orifice transluminal endoscopic surgery access site
  • Brian G. Turner, Min-Chan Kim, Denise W. Gee, Abdulmetin Dursun, Mari Mino-Kenudson, Edward S. Huang, Patricia Sylla, David W. Rattner, William R. Brugge
| Article suivant Article suivant
  • Continuing Medical Education Exam: April 2011
  • Raquel E. Davila, Jeffrey H. Lee, William Ross, Shou-Jiang Tang, G.S. Raju, Glenn M. Eisen

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.