Résumé

Background

Drug-eluting stents with low late loss may be particularly beneficial in small coronary arteries. We therefore examined whether the everolimus-eluting stent is superior to the paclitaxel-eluting stent in patients treated with 2.5-mm stents in the SPIRIT III trial.

Methods

The SPIRIT III trial was a prospective, multicenter, randomized (2:1; XIENCE V: TAXUS Express) trial in which 1002 patients were enrolled. One or more 2.5-mm stents were implanted in 160 patients in the XIENCE V arm, and 59 patients, in the TAXUS arm. Mean vessel diameter was 2.36 ± 0.30 and 2.34 ± 0.33 mm in the XIENCE V and TAXUS groups, respectively (P = .69).

Results

At 9 months, XIENCE V compared to TAXUS reduced the rates of major adverse cardiac events (cardiac death, myocardial infarction, or ischemic target lesion revascularization) from 12.5% to 3.2% (P = .02) and target vessel failure (cardiac death, reinfarction, or ischemic target vessel revascularization) from 16.1% to 5.2% (P = .02), the differences being driven primarily by reductions in target lesion revascularization (12.5% vs 1.3%; P = .002). In-stent late loss was significantly reduced by XIENCE V when compared to TAXUS (0.54 ± 0.74 vs 0.11 ± 0.43 mm, P = .01), as was In-segment binary angiographic restenosis (20.8% vs 4.1%, P = .02).

Conclusions

In this post hoc analysis from the SPIRIT III trial, the XIENCE V 2.5-mm stent significantly reduced clinical and angiographic restenosis compared to the TAXUS 2.5-mm stent, further supporting the hypothesis that lower late loss is beneficial in small vessel disease.

Le texte complet de cet article est disponible en PDF.

Plan


© 2009  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 158 - N° 6

P. 1005-1010 - décembre 2009 Retour au numéro
Article précédent Article précédent
  • Safety and feasibility of adjunctive antiplatelet therapy with intravenous elinogrel, a direct-acting and reversible P2Y12 ADP-receptor antagonist, before primary percutaneous intervention in patients with ST-elevation myocardial infarction: The Early Rapid ReversAl of Platelet ThromboSis with Intravenous Elinogrel before PCI to Optimize REperfusion in Acute Myocardial Infarction (ERASE MI) pilot trial
  • Jeffrey S. Berger, Matthew T. Roe, C. Michael Gibson, Rakhi Kilaru, Cynthia L. Green, Laura Melton, James D. Blankenship, D. Christopher Metzger, Christopher B. Granger, Daniel D. Gretler, Cindy L. Grines, Kurt Huber, Uwe Zeymer, Pawel Buszman, Robert A. Harrington, Paul W. Armstrong
| Article suivant Article suivant
  • High incidence of TIMI flow 0 to I in patients with ST-elevation myocardial infarction without electrocardiographic lytic criteria
  • Jaume Figueras, Ignacio Ferreira-González, Marcelo Rizzo, Oscar Alcalde, José A. Barrabés, Enric Domingo, Rosa M. Lidón, Josefa Cortadellas

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.