S'abonner

Use of Lean and Six Sigma Methodology to Improve Operating Room Efficiency in a High-Volume Tertiary-Care Academic Medical Center - 10/08/11

Doi : 10.1016/j.jamcollsurg.2011.02.009 
Robert R. Cima, MD, MA, FACS a, Michael J. Brown, MD b, , James R. Hebl, MD b, Robin Moore, MBA f, James C. Rogers, PMP e, Anantha Kollengode, PhD, MBA d, Gwendolyn J. Amstutz, MHA a, Cheryl A. Weisbrod, RN, MS c, Bradly J. Narr, MD b, Claude Deschamps, MD, FACS a

Surgical Process Improvement Team, Mayo Clinic, Rochester

a Department of Surgery, Mayo Clinic College of Medicine, Rochester, MN 
b Department of Anesthesia, Mayo Clinic College of Medicine, Rochester, MN 
c Department of Nursing, Mayo Clinic College of Medicine, Rochester, MN 
d Research Administration, Mayo Clinic, Rochester, MN 
e Systems and Procedures, Mayo Clinic, Rochester, MN 
f Financial Analysis and Planning, Mayo Clinic, Rochester, MN 

Correspondence address: Michael J Brown, MD, Department of Anesthesia, Mayo Clinic College of Medicine, 200 First St SW, Rochester, MN 55905

Résumé

Background

Operating rooms (ORs) are resource-intense and costly hospital units. Maximizing OR efficiency is essential to maintaining an economically viable institution. OR efficiency projects often focus on a limited number of ORs or cases. Efforts across an entire OR suite have not been reported. Lean and Six Sigma methodologies were developed in the manufacturing industry to increase efficiency by eliminating non−value-added steps. We applied Lean and Six Sigma methodologies across an entire surgical suite to improve efficiency.

Study Design

A multidisciplinary surgical process improvement team constructed a value stream map of the entire surgical process from the decision for surgery to discharge. Each process step was analyzed in 3 domains, ie, personnel, information processed, and time. Multidisciplinary teams addressed 5 work streams to increase value at each step: minimizing volume variation; streamlining the preoperative process; reducing nonoperative time; eliminating redundant information; and promoting employee engagement. Process improvements were implemented sequentially in surgical specialties. Key performance metrics were collected before and after implementation.

Results

Across 3 surgical specialties, process redesign resulted in substantial improvements in on-time starts and reduction in number of cases past 5 pm. Substantial gains were achieved in nonoperative time, staff overtime, and ORs saved. These changes resulted in substantial increases in margin/OR/day.

Conclusions

Use of Lean and Six Sigma methodologies increased OR efficiency and financial performance across an entire operating suite. Process mapping, leadership support, staff engagement, and sharing performance metrics are keys to enhancing OR efficiency. The performance gains were substantial, sustainable, positive financially, and transferrable to other specialties.

Le texte complet de cet article est disponible en PDF.

Abbreviations and Acronyms : Gen/CRS, GYN, LSS, MCR, OR, RMH, SPI, TS


Plan


 Disclosure Information: Nothing to disclose.
 Surgical Process Improvement Team, Mayo Clinic, Rochester: Timothy O Wilson, MD, W Richard Marsh, MD, David R Danielson, MD, Mark B Koch, MBA, Chad E Goetz, Sarah R Pool, RN, MS, Karen A Spaulding, RN, MS.


© 2011  American College of Surgeons. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 213 - N° 1

P. 83-92 - juillet 2011 Retour au numéro
Article précédent Article précédent
  • Discussion
| Article suivant Article suivant
  • Discussion

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.