Quantitative Blush Evaluator accurately quantifies microvascular dysfunction in patients with ST-elevation myocardial infarction: Comparison with cardiovascular magnetic resonance - 09/08/11

Doi : 10.1016/j.ahj.2011.04.014 
Italo Porto, MD, PhD a, , d , Christian Hamilton-Craig, MBBS, FRACP a, c, d, Giovanni Luigi De Maria, MD a, Rocco Vergallo, MD a, Giorgio Cautilli, MD a, Leonarda Galiuto, MD, PhD, FACC a, Francesco Burzotta, MD, PhD a, Antonio Maria Leone, MD, PhD a, Giampaolo Niccoli, MD, PhD a, Luigi Natale, MD b, Lorenzo Bonomo, MD b, Filippo Crea, MD, FESC, FACC a
a Department of Cardiovascular Medicine, Catholic University of the Sacred Heart, Rome, Italy 
b Department of BioImaging, Catholic University of the Sacred Heart, Rome, Italy 
c University of Queensland, Brisbane, Australia 

Reprint requests: Italo Porto, MD, PhD, Department of Cardiovascular Medicine, Catholic University of the Sacred Heart, L.go A. Gemelli, 8-00168 Rome, Italy.

Résumé

Background

After ST-elevation myocardial infarction (STEMI), microvascular obstruction (MVO) can be assessed using semiquantitative angiographic “blush” scores subject to interoperator variability. Quantitative Blush Evaluator (QuBE) is a free computer-calculated algorithm that evaluates myocardial blush on a continuous scale with improved reproducibility. We aimed to compare QuBE with cardiovascular magnetic resonance (CMR) in detecting MVO and its severity.

Methods

Fifty-two STEMI treated with successful primary percutaneous coronary intervention were enrolled. Quantitative Blush Evaluator and electrocardiographic sum ST-segment resolution were blindly calculated. All patients underwent CMR 4 to 7 days after STEMI for assessment of infarct size (IS), myocardial salvage index, MVO (both as first-pass MVO and delayed-enhancement MVO [DE-MVO]), and presence of intramyocardial hemorrhage on T2-weighted sequences.

Results

Quantitative Blush Evaluator values were inversely related to IS (R = −0.4, P = .008), DE-MVO (R = −0.7, P < .001), and first-pass MVO (R = −0.4, P = .002) and positively related to myocardial salvage index (R = 0.4, P = .007). Moreover, patients with intramyocardial hemorrhage had significantly lower QuBE values (3.9, 3.5-8.0 vs 12.2, 8.2-16.0, P = .001) than those without. At receiver operating characteristic curve analysis, QuBE accounted for an area under the curve of 0.88 (95% CI 0.7-0.9, P = .001) for both DE-MVO and hemorrhage detection and performed significantly better than ST resolution.

Conclusions

Quantitative Blush Evaluator score correlates with IS and microvascular dysfunction by CMR and can be considered as an accurate tool for the assessment of MVO in clinical practice. Quantitative Blush Evaluator is a useful quantitative angiographic technique for the assessment of myocardial reperfusion after STEMI.

Le texte complet de cet article est disponible en PDF.

Plan


© 2011  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 162 - N° 2

P. 372 - août 2011 Retour au numéro
Article précédent Article précédent
  • Relationship between clopidogrel-induced platelet P2Y12 inhibition and stent thrombosis or myocardial infarction after percutaneous coronary intervention—A case-control study
  • Christoph Varenhorst, Sasha Koul, David Erlinge, Bo Lagerqvist, Agneta Siegbahn, Lars Wallentin, Stefan James
| Article suivant Article suivant
  • Clinical characteristics of patients with asymptomatic recurrences of atrial fibrillation in the Gruppo Italiano per lo Studio della Sopravvivenza nell'Infarto Miocardico–Atrial Fibrillation (GISSI-AF) trial
  • Marcello Disertori, Federico Lombardi, Simona Barlera, Aldo Pietro Maggioni, Chiara Favero, Maria Grazia Franzosi, Donata Lucci, Lidia Staszewsky, Gianna Fabbri, Silvia Quintarelli, Leopoldo Bianconi, Roberto Latini

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.