S'abonner

A prospective study of the diagnostic utility of sputum Gram stain in pneumonia - 07/08/11

Doi : 10.1016/j.jinf.2009.05.011 
Stavros Anevlavis a, , Niki Petroglou b, Athanasios Tzavaras b, Efstratios Maltezos c, Ioannis Pneumatikos d, Marios Froudarakis a, Eleftherios Anevlavis b, Demosthenes Bouros a
a Department of Pneumonology, Medical School, Democritus University of Thrace, Dragana, Alexandroupolis, Greece 
b 1st Internal Medicine Department, Konstantopoulio Hospital, Athens, Greece 
c 2nd Internal Medicine Department, Medical School, Democritus University of Thrace, Dragana, Alexandroupolis, Greece 
d Intensive Care Unit, Medical School, Democritus University of Thrace, Dragana, Alexandroupolis, Greece 

Corresponding author. Tel.: +30 6944755343.

Summary

Introduction

Sputum Gram stain and culture have been said to be unreliable indicators of the microbiological diagnosis of bacterial pneumonia. The etiological diagnosis of pneumonia is surrounded by great degree of uncertainty. This uncertainty should be and can be calculated and incorporated in the diagnosis and treatment.

Study objectives

To determine the diagnostic accuracy and diagnostic value of sputum Gram stain in etiological diagnosis and initial selection of antimicrobial therapy of bacterial community acquired pneumonia (CAP).

Design-Method

Prospective study of 1390 patients with CAP admitted January 2002–June 2008, to our institutions. Of the 1390 patients, 178 (12.8%) fulfilled the criteria for inclusion into this study (good-quality sputa and presence of the same microorganism in blood and sputum cultures which was used as gold standard for assessing the diagnostic accuracy and diagnostic value of sputum Gram stain).

Results

The sensitivity of sputum Gram stain was 0.82 for Pneumococcal pneumonia, 0.76 for Staphylococcal pneumonia, 0.79 for Haemophilus influenzae pneumonia and 0.78 for Gram-negative bacilli pneumonia. The specificity of sputum Gram stain was 0.93 for Pneumococcal pneumonia, 0.96 for Staphylococcal pneumonia, 0.96 for H. influenzae pneumonia and 0.95 for Gram-negative bacilli pneumonia. The positive likelihood ratio (LR+) was 11.58 for Pneumococcal pneumonia, 19.38 for Staphylococcal pneumonia, 16.84 for H. influenzae pneumonia, 14.26 for Gram-negative bacilli pneumonia. The negative likelihood ratio (LR–) was 0.20 for Pneumococcal pneumonia, 0.25 for Staphylococcal pneumonia, 0.22 for H. influenzae pneumonia, and 0.23 for Gram-negative bacilli pneumonia.

Conclusions

Sputum Gram stain is a dependable diagnostic test for the early etiological diagnosis of bacterial CAP that helps in choosing orthological and appropriate initial antimicrobial therapy.

Le texte complet de cet article est disponible en PDF.

Keywords : Gram stain, Community acquired pneumonia, Diagnostic accuracy, Diagnostic value


Plan


© 2009  The British Infection Society. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 59 - N° 2

P. 83-89 - août 2009 Retour au numéro
Article précédent Article précédent
  • Emergence of invasive pneumococcal disease caused by multidrug-resistant serotype 19A among children in Barcelona
  • Carmen Muñoz-Almagro, Cristina Esteva, Maria Fernandez de Sevilla, Laura Selva, Amadeu Gene, Roman Pallares
| Article suivant Article suivant
  • New FTIR methodology for the evaluation of 13C/12C isotope ratio in Helicobacter pylori infection diagnosis
  • Oriana Motta, Francesco De Caro, Floriana Quarto, Antonio Proto

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.