S'abonner

Safety and efficacy of femoral vascular closure devices in patients undergoing primary percutaneous coronary intervention for ST-elevation myocardial infarction - 06/08/11

Doi : 10.1016/j.ahj.2011.03.009 
Óscar Prada-Delgado, MD, Rodrigo Estévez-Loureiro, MD , Ramón Calviño-Santos, MD, Eduardo Barge-Caballero, PhD, Jorge Salgado-Fernández, MD, Pablo Piñón-Esteban, MD, Jose Manuel Vázquez-Rodríguez, PhD, Guillermo Aldama-López, MD, Xacobe Flores-Ríos, PhD, María Rita Soler-Martín, PhD, Nicolás Vázquez-González, MD, Alfonso Castro-Beiras, PhD
 Interventional Cardiology Unit, Department of Cardiology, Complejo Hospitalario Universitario A Coruña, A Coruña, Spain 

Reprint requests: Rodrigo Estévez-Loureiro, MD, Department of Cardiology, As Xubias 84, 15006 La Coruña, Spain.

Résumé

Background

The use of vascular closure devices (VCDs) for the reduction of access site complications following percutaneous coronary intervention (PCI) remains controversial. Patients undergoing primary PCI for acute ST-segment elevation myocardial infarction (STEMI) are at high risk of femoral artery complications. A lack of information exists regarding the use of VCDs in this group of patients because they have been routinely excluded from randomized trials. This study sought to evaluate the safety and efficacy of the routine use of VCDs after primary PCI.

Methods

A total of 558 consecutive patients undergoing primary PCI for STEMI via femoral route were studied for in-hospital outcomes through a prospective registry from January 2003 to December 2008. The primary end point was the presence of major vascular complication (MVC) defined as a composite of fatal access site bleeding, access site complication requiring interventional or surgical correction, or access site bleeding with ≥3 g/dL drop in hemoglobin or requiring blood transfusion.

Results

Of the total patients, 464 (83.2%) received a VCD; and manual compression was used in 94 patients (16.8%). Major vascular complication occurred in 5.2% of patients. The risk of MVC was significantly lower with VCDs compared with manual compression (4.3% vs 9.6%, P = .036). Multivariable logistic regression analysis determined that VCD use remained an independent predictor of lower rate of MVC (odds ratio 0.38, 95% CI 0.17-0.91).

Conclusions

The use of VCDs in patients undergoing primary PCI for STEMI is safe and is associated with lower rates of MVC compared with manual compression.

Le texte complet de cet article est disponible en PDF.

Plan


© 2011  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 161 - N° 6

P. 1207-1213 - juin 2011 Retour au numéro
Article précédent Article précédent
  • The possibility of delayed arterial healing 5 years after implantation of sirolimus-eluting stents: Serial observations by coronary angioscopy
  • Masanori Yamamoto, Masamichi Takano, Daisuke Murakami, Toru Inami, Nobuaki Kobayashi, Sigenobu Inami, Kentaro Okamatsu, Takayoshi Ohba, Chikao Ibuki, Noritake Hata, Yoshihiko Seino, Ik-Kyung Jang, Kyoichi Mizuno
| Article suivant Article suivant
  • Physiologic decrease of ventilatory response to exercise in the second decade of life in healthy children
  • Alessandro Giardini, Dolf Odendaal, Sachin Khambadkone, Graham Derrick

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.