S'abonner

Left ventricular strain and untwist in hypertrophic cardiomyopathy: Relation to exercise capacity - 05/08/11

Doi : 10.1016/j.ahj.2010.02.002 
Khalid Abozguia, MBBCh, MRCP a, , Ganesh Nallur-Shivu, MRCP a, Thanh T. Phan, MRCP, PhD a, Ibrar Ahmed, MRCP a, Rajat Kalra a, Rebekah A. Weaver, MSc a, William J. McKenna, BA, MD, DSc, FRCP b, John E. Sanderson, MA, MD, FRCP, FACC, FHKAM a, c, Perry Elliott, MD, FRCP, FACC, FESC b, Michael P. Frenneaux, MD, FRCP, FACC, FMedSci a, d
a Department of Cardiovascular Medicine, Medical School, University of Birmingham, Edgbaston, Birmingham, United Kingdom 
b Department of Cardiology, The Heart Hospital, University College London Hospitals, London, United Kingdom 
c Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, China 
d School of Medicine and Dentistry, University of Aberdeen, Polwarth Building, Aberdeen, United Kingdom 

Reprint requests: Khalid Abozguia, MBBCh, MRCP UK, Department of Cardiovascular Medicine, Medical School, University of Birmingham, Edgbaston, B15 2TT Birmingham, United Kingdom.

Résumé

Background

Nonobstructive hypertrophic cardiomyopathy (nHCM) is often associated with reduced exercise capacity despite hyperdynamic systolic function as measured by left ventricular ejection fraction. We sought to examine the importance of left ventricular strain, twist, and untwist as predictors of exercise capacity in nHCM patients.

Methods

Fifty-six nHCM patients (31 male and mean age of 52 years) and 43 age- and gender-matched controls were enrolled. We measured peak oxygen consumption (peak Vo2) and acquired standard echocardiographic images in all participants. Two-dimensional speckle tracking was applied to measure rotation, twist, untwist rate, strain, and strain rate.

Results

The nHCM patients exhibited marked exercise limitation compared with controls (peak Vo2 23.28 ± 6.31 vs 37.70 ± 7.99 mL/[kg min], P < .0001). Left ventricular ejection fraction in nHCM patients and controls was similar (62.76% ± 9.05% vs 62.48% ± 5.82%, P = .86). Longitudinal, radial, and circumferential strain and strain rate were all significantly reduced in nHCM patients compared with controls. There was a significant delay in 25% of untwist in nHCM compared with controls. Both systolic and diastolic apical rotation rates were lower in nHCM patients. Longitudinal systolic and diastolic strain rate correlated significantly with peak Vo2 (r = −0.34, P = .01 and r = 0.36, P = .006, respectively). Twenty-five percent untwist correlated significantly with peak Vo2 (r = 0.36, P = .006).

Conclusions

In nHCM patients, there are widespread abnormalities of both systolic and diastolic function. Reduced strain and delayed untwist contribute significantly to exercise limitation in nHCM patients.

Le texte complet de cet article est disponible en PDF.

Plan


© 2010  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 159 - N° 5

P. 825-832 - mai 2010 Retour au numéro
Article précédent Article précédent
  • Association of Health Aging and Body Composition (ABC) Heart Failure score with cardiac structural and functional abnormalities in young individuals
  • Sachin Gupta, Jarett D. Berry, Colby R. Ayers, Susan A. Matulevicius, Ronald M. Peshock, Parag C. Patel, David W. Markham, Mark H. Drazner
| Article suivant Article suivant
  • Prognostic impact of baseline and serial changes in electrocardiographic left ventricular hypertrophy in resistant hypertension
  • Gil Fernando Salles, Claudia Regina Lopes Cardoso, Roberto Fiszman, Elizabeth Silaid Muxfeldt

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.