S'abonner

Can direct immunofluorescence testing still be accurate if performed on biopsy specimens after brief inadvertent immersion in formalin? - 28/07/11

Doi : 10.1016/j.jaad.2010.06.019 
Joshua Arbesman, MD c, Raminder Grover, MD a, b, , Thomas N. Helm, MD c, Ernst H. Beutner, PhD a, b, c
a Beutner Laboratories, University at Buffalo, Buffalo, New York 
b Department of Microbiology and Immunology, University at Buffalo, Buffalo, New York 
c Department of Dermatology, University at Buffalo, Buffalo, New York 

Reprint requests: Raminder Grover, MD, Beutner Laboratories Inc, 3580 Harlem Rd, PO Box 26, Buffalo, NY 14215.

Abstract

Background

Direct immunofluorescence is useful in the diagnosis of autoimmune, vesiculobullous, and connective tissue diseases. Michel medium is typically indicated for transport, but clinicians may inadvertently place samples into formalin.

Objective

We set out to determine the amount of time that specimens can remain in 10% buffered formalin and still retain their diagnostic properties.

Methods

Biopsy samples were examined from cases with established diagnoses of bullous pemphigoid (n = 12), dermatitis herpetiformis (n = 6), and pemphigus vulgaris (n = 6) and exposed to formalin for time points ranging from 2 minutes to 4 hours.

Results

We found that immunoreactants were detectable in the majority of samples when subjected to 2 minutes of formalin exposure. Dermatitis herpetiformis and pemphigoid samples retained immunogenicity for 10 minutes, whereas pemphigus showed reduced immunogenicity for all samples studied. A nonimmunologic nuclear fluorochroming pattern was noted in some of the specimens after formalin immersion.

Limitations

Sample size, only examining 3 disease processes, and samples already having been in Michel medium were the major limitations in the study.

Conclusion

In direct immunofluorescence studies, formalin exposure to biopsy specimens causes two types of artifactual changes: (1) the shortest exposure (2 minutes) causes complete loss of diagnostic markers of pemphigus; and (2) prolonged exposure changes tissue to a form that allows fluorescein-labeled antibodies to give fluorochroming reactions of nuclei (which can be mistaken for in vivo antinuclear antibody reactions of lupus erythematosus). After time intervals of 10 minutes to 2 hours, direct immunofluorescence studies of proven cases of bullous pemphigoid and dermatitis herpetiformis retained variable levels of specific reactivity.

Le texte complet de cet article est disponible en PDF.

Key words : antinuclear antibody, bullous pemphigoid, dermatitis herpetiformis, direct immunofluorescence, formalin, Michel medium, pemphigus


Plan


 Funding sources: None.
 Conflicts of interest: None declared.


© 2010  American Academy of Dermatology, Inc.. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 65 - N° 1

P. 106-111 - juillet 2011 Retour au numéro
Article précédent Article précédent
  • Accelerated takedown of the paramedian forehead flap at 1 week: Indications, technique, and improving patient quality of life
  • Brian Somoano, Jeremy Kampp, Hayes B. Gladstone
| Article suivant Article suivant
  • A study of histologic and immunophenotypical staining patterns in cutaneous lymphoid hyperplasia
  • Reuven Bergman, Khozayma Khamaysi, Ziad Khamaysi, Yehudit Ben Arie

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.