Étude dosimétrique comparative de la vertébroplastie et de la kyphoplastie sous double guidage : scanner et fluoroscopique - 01/07/11
Summary |
Objectives |
The goals of this study is to evaluate and compare the irradiation received by the practitioner when performing percutaneous vertebroplasty or kyphoplasty guided by CT and fluoroscopy, for precise anatomical sites.
Methods |
For each intervention, radiothermoluminescent dosimeters were carefully positioned on both orbitals, both hands, and both ankles of the practitioner.
Results |
Twenty-four vertebroplasties were performed in 18 patients and nine kyphoplasties on seven patients. The anatomical site that is most exposed to radiation is the right hand. The two other sites subjected to irradiation are the left hand and the left orbital. This study demonstrates a significant correlation between the irradiation dose and fluoroscopy duration, reflecting both the quantity of primary-beam radiation and backscattered radiation.
Conclusion |
The radiation dose to radiologist is more important for kyphoplasty procedures than vertebroplasty.
Le texte complet de cet article est disponible en PDF.Keywords : Radiation dose, Vertebroplasty, Kyphoplasty, CT guidance, Fluoroscopy