Images de soustraction TEMP, en double isotope, 99mTc-sestamibi/123I fusionnées au scanner : intérêt chez des patients présentant une hyperparathyroïdie - 22/03/11

Doi : 10.1016/j.mednuc.2010.12.002 
X. Poullias a, , M. Guernou b, S. Hapdey a, A. Hitzel c, A. Salles a, P. Vera a, A. Edet-Sanson a
a Service de médecine nucléaire, centre Henri-Becquerel, 1, rue d’Amiens, 76000 Rouen, France 
b Centre cardiologique du Nord, Saint-Denis, France 
c CHU de Toulouse, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 9
Iconographies 4
Vidéos 0
Autres 0

Résumé

Objectifs

Évaluer l’intérêt des images de soustraction TEMP fusionnées au scanner (S/CT), par rapport à la soustraction planaire (S/PL) et à l’échographie (Ech) dans le cadre d’hyperparathyroïdisme.

Patients et méthodes

Cette étude rétrospective a porté sur 99 patients atteints d’une hyperparathyroïdie, adressés pour une scintigraphie, une échographie orientée par celle-ci et opérés secondairement (Chir). Deux heures après injection d’123I libre et 30 minutes après celle de 99mTc-Sestamibi, des acquisitions en double isotope, planaires et TEMP/TDM, ont été réalisées pour obtenir des images de soustraction : S/PL et S/CT. En aveugle des résultats chirurgicaux, l’interprétation S/PL et S/CT a été effectuée conjointement par deux médecins nucléaires. Pour chaque modalité Ech, S/PL, S/CT et Chir, en cas d’anomalie à droite ou à gauche, le résultat a été considéré comme positif. Les tailles des structures retrouvées ont été mesurées pour Ech, S/CT et la chirurgie.

Résultats

Au total, 75 patients ont bénéficié d’une chirurgie. Les résultats ont donc concerné 150 régions cervicales droites et gauches. Du tissu parathyroïdien (adénome/hyperplasie) a été réséqué chirurgicalement chez 70 patients, soit 79 régions cervicales. Les sensibilités et spécificités par rapport à la chirurgie étaient respectivement 69/96, 82/91 et 83/93 pour l’Ech, S/PL et S/CT avec mesure d’accord kappa de 0,64, 0,73 et 0,76. Pour la taille des lésions, il existait une corrélation entre l’Ech, S/CT et Chir ; par rapport au S/CT, les dimensions Écho restant plus proches des dimensions Chir (test Spearman 0,65 versus 0,31). Concernant la localisation des lésions parathyroïdiennes, sur 79 lésions cervicales opérées, 63 correspondaient à une lésion tissulaire visualisée sur l’imagerie de fusion S/CT. Ainsi, dans 80 % des cas, les rapports anatomiques de la lésion ont pu être précisés.

Conclusion

Même si les images de soustraction TEMP fusionnées au scanner présentent une sensibilité proche des images de soustraction planaire, la réalisation de cette modalité permet le plus souvent de visualiser la lésion pour en définir sa taille et ses rapports anatomiques. Ces éléments sont une aide pour la prise en charge chirurgicale.

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

To assess dual-tracer imaging of hybrid SPECT/CT (S/CT) compared to planar scintigraphy (S/PL) and ultrasounds (US), in preoperative localization hyperparathyroidism.

Methods

Dual tracer S/CT, S/PL and US for preoperative localization were performed in 99 patients with hyperparathyroidism. Patients with single-gland and multiple gland disease (MGD) were evaluated. For S/PL and S/CT, 15 MBq of 123I were given and 2hours later, 555 MBq/kg of 99mTc-MIBI was injected. Images were acquired simultaneously using appropriate windows in S/PL and S/CT, then compared to US. Thus, the predicted positions were compared to the intraoperative findings and abnormal parathyroid glands were measured.

Results

Seventy-five patients underwent invasive surgery, which served as standard. Sixty-seven adenomas and 17 MGD were found on 70 patients. Sensitivity for US, S/PL and S/CT was respectively 69, 82 and 83%; and specificity was 96, 91 and 93% with an overall kappa-coefficient of 0.64, 0.73 and 0.76. US, S/PL and S/CT were correlated with the size of abnormal glands even if US remains the most accurate measuring technique. S/CT was able to predict the true position of the abnormal gland in 80% of cases.

Conclusion

Dual-isotope planar imaging and S/CT were statistically significantly superior to US imaging in sensitivity. The addition of CT to SPECT further improves parathyroid adenoma localization and predicts the size, which can help for mini-invasive surgery.

Le texte complet de cet article est disponible en PDF.

Mots clés : Hyperparathyroïdisme, TEMP/TDM, Méthode de soustraction en double isotope

Keywords : Hyperparathyroidism, SPECT/CT, Dual-tracer imaging


Plan


© 2011  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 35 - N° 3

P. 96-104 - mars 2011 Retour au numéro
Article précédent Article précédent
  • Scintigraphie des parathyroïdes et tomoscintigraphie
  • C. Jeanguillaume
| Article suivant Article suivant
  • Scintigraphie des parathyroïdes double isotope 99mTc-MIBI/123I dans l’hyperparathyroïdisme primaire : comparaison entre un protocole d’acquisition planaire et une TEMP de soustraction couplée à la TDM
  • S. Hassler, F. Hubele, A. Constantinesco, C. Goetz

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.