Segmentation automatique du volume tumoral des cancers pulmonaires non à petites cellules sur la 18F-FDG TEP-TDM en vue d’un traitement par radiothérapie - 21/07/09

Doi : 10.1016/j.mednuc.2009.03.005 
C. Boursot a, , A. Le Borgne b, I. Barillot c, Y. Venel a, A. de Muret d, J.-L. Baulieu a, b, C. Prunier-Aesch a, b
a Service de médecine nucléaire, CHRU de Tours-Bretonneau, 37044 Tours cedex 9, France 
b Inserm U930, CHRU de Tours-Bretonneau, 37044 Tours cedex 9, France 
c Service de radiothérapie, CHRU de Tours-Bretonneau, 37044 Tours cedex 9, France 
d Service d’anatomie pathologique, CHRU de Tours-Trousseau, 37044 Tours cedex 9, France 

Auteur correspondant. Service de médecine nucléaire, hôpital Bretonneau, CHRU de Tours, 2, boulevard Tonnellé, 37000 Tours, France.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 10
Iconographies 2
Vidéos 0
Autres 0

Résumé

Objectifs

La radiothérapie est indiquée dans certains stades du cancer bronchopulmonaire non à petites cellules (CBNPC). Elle nécessite une délimitation préalable de la tumeur par le radiothérapeute grâce à un contourage sur le scanner, mais ce procédé ne tient pas compte des caractéristiques biologiques de la cible et reste opérateur dépendant. Pour optimiser le volume d’irradiation, plusieurs équipes ont élaboré des techniques de segmentation automatique sur la TEP FDG, encore en cours d’évaluation.

Matériels et méthodes

Nous avons réalisé une étude rétrospective portant sur 17 patients pour évaluer les différences entre les volumes obtenus par contourage scannographique avec ceux fournis par trois algorithmes de segmentation automatique se basant sur la TEP FDG (Black et al., Nestle et al. et Tylski et al.). Une confrontation avec le volume histologique a été réalisée en cas d’exérèse chirurgicale de la tumeur.

Résultats

Les trois méthodes sous-évaluaient le volume tumoral par rapport au scanner en moyenne de 8 % pour Nestle et al., 22 % pour Black et al. et 30 % pour Tylski et al. ; mais ces résultats cachaient des disparités qui tendaient à s’atténuer avec un regroupement des tumeurs par taille. Les plus grandes différences étaient imputables à des fixations hétérogènes en TEP FDG (nécroses, spicules, atélectasies).

Conclusion

La méthode de Black et al. était la plus discordante. Pour les tumeurs inférieures à 45cm3, l’algorithme de Nestle et al. avait tendance à surévaluer le volume scannographique, mais permettait ainsi de tenir compte de l’extension néoplasique microscopique. Enfin, la technique de Tylski et al. sous-évaluait nettement le volume cible mais présentait une approche intéressante (correction d’effet de volume partiel).

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

Radiotherapy belongs to the treatment of certain stages of non-small cell lung cancer. It requires a preliminary delimitation of the tumour by the radiotherapist with a contouring of the tumour on the CT but this method does not take into account the biological characteristics of the target and remains dependent on the operator. To optimize the irradiation volume, several teams created methods of automatic segmentation on the PET-CT, still under evaluation.

Material and methods

We undertook a retrospective study on 17 patients to evaluate the difference between obtained volumes by CT delimitation with those deduced by three algorithms of automatic segmentation based on PET-CT (Black et al., Nestle et al. and Tylski et al.). A confrontation with histological tumoral volume has been carried on in case of surgery.

Results

On average, the three methods under evaluated tumoral volume compared to the CT of 8% for Nestle et al., 22% for Black et al. and 30% for Tylski et al., but these results hide disparities, which tended to decrease with a grouping of tumours by size. The most important differences were due to heterogeneous uptake of FDG (necrosis, spicules, atelectasis).

Conclusion

The method of Black et al. was the most discrepant one. For tumours less than 45cm3, Nestle’s et al. algorithm tends to overestimate the CT volume and thus makes it possible to integrate safety margins into final volume (microscopic extension). The method of Tylski et al. presents an interesting approach (correction of partial volume effect) but still requires developments because it under evaluates too much the target volume.

Le texte complet de cet article est disponible en PDF.

Mots clés : TEP FDG, Cancers pulmonaires, Segmentation automatique, Radiothérapie, Gross tumoural volume (GTV)

Keywords : FDG–PET, Lung cancer, Automatic segmentation, Radiotherapy, Gross tumoural volume (GTV)


Plan


© 2009  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 33 - N° 7

P. 440-449 - juillet 2009 Retour au numéro
Article précédent Article précédent
  • Intérêt de l’imagerie hybride TEMP/TDM pour la scintigraphie des récepteurs de la somatostatine dans le bilan des tumeurs endocrines gastro-entéro-pancréatiques
  • B. Scarwell, S. Burg, M.-H. Bouin-Pineau, R. Perdrisot
| Article suivant Article suivant
  • Ectopie de la parathyroïde objectivée par la scintigraphie au MIBI-Tc 99m. À propos de deux cas. Expérience du service de médecine nucléaire – CHU Ibn Sina-Rabat
  • F. Berehou, I. Ghfir, N. Ben Rais

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.