S'abonner

Reliability of a modified Modic classification of bone marrow changes in lumbar spine MRI - 30/04/09

Doi : 10.1016/j.jbspin.2008.09.012 
Fouad Fayad a, b, , Marie-Martine Lefevre-Colau c, Jean-Luc Drapé d, Antoine Feydy d, Nathalie Chemla d, Nathalie Quintéro a, François Rannou a, Serge Poiraudeau a, Jacques Fermanian e, Michel Revel a
a Department of Physical Medicine and Rehabilitation, Cochin Hospital (AP-HP), Paris Descartes University, 75679 Paris Cedex 14, France 
b Department of Rheumatology, Hotel-Dieu de France Hospital, Saint-Joseph University, Beirut, Lebanon, France 
c Department of Physical Medicine and Rehabilitation, Corentin-Celton Hospital (AP-HP), Paris Descartes University, Issy-les-Moulineaux, France 
d Department of Radiology B, Cochin Hospital (AP-HP), Paris Descartes University, Paris, France 
e Department of Biostatistics, Necker Hospital (AP-HP), Paris Descartes University, Paris, France 

Corresponding author: Fouad Fayad, Department of Physical Medicine and Rehabilitation, Cochin Hospital (AP-HP), Paris Descartes University, 27 rue du Faubourg Saint Jacques, 75679 Paris Cedex 14, France. Tel.: +33 1 58 41 25 41; fax: +33 1 58 41 25 45.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 4
Iconographies 4
Vidéos 0
Autres 0

Abstract

Objective

The purpose of this study was to determine the intra- and interobserver reliability of a modified Modic classification for bone marrow changes seen on lumbar spine magnetic resonance imaging (MRI), taking into consideration mixed signals.

Methods

Lumbar MRI scans from 94 patients with low back pain were assessed independently by 2 spine specialists (senior [senior1], junior) and a radiologist (senior2). One reviewer (senior1) assessed the MR images twice at a three-week interval for evaluation of intraobserver reliability. Senior2 and junior reviewers assessed the MR images once. Pure edema endplate signal changes were classified as Modic type I, and pure fatty endplate changes as Modic type II. A mixture of types I and II but predominantly edema signal changes was classified as Modic I-2 and a mixture of types I and II but predominantly fatty changes was classified as Modic II-1.

Results

The intraobserver agreement was excellent (weighted kappa 0.85). The interobserver agreement was moderate to substantial (weighted kappa range 0.56–0.74). Interobserver reliability depended on the experience of the observer, thus highlighting the importance of a learning curve.

Conclusion

This study shows that the modified Modic classification is reliable and easy to apply for observers with different clinical experience. The inclusion of mixed marrow changes in the modified classification may have clinical and therapeutic implications.

Le texte complet de cet article est disponible en PDF.

Keywords : Magnetic Resonance Imaging, Lumbar spine, Modic changes, Reliability


Plan


© 2008  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 76 - N° 3

P. 286-289 - mai 2009 Retour au numéro
Article précédent Article précédent
  • Biering-Sorensen test scores in coal miners
  • Yasin Tekin, Ozgur Ortancil, Handan Ankarali, Aynur Basaran, Selda Sarikaya, Senay Ozdolap
| Article suivant Article suivant
  • Ankylosing spondylitis and systemic sclerosis: A rare combination
  • Dieu-Donné Ouédraogo, Elisabeth Palazzo, Mireille Nlomé-Nzé, Nathalie Somogyi-Demerjian, Olivier Meyer

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.