S'abonner

Three or four parts complex proximal humerus fractures: Hemiarthroplasty versus reverse prosthesis: A comparative study of 40 cases - 05/03/09

Doi : 10.1016/j.otsr.2008.09.002 
D. Gallinet a, , P. Clappaz b, P. Garbuio a, Y. Tropet a, L. Obert a
a Department of Orthopaedics and Traumatology, Academic Hospital Center Jean Minjoz, boulevard Fleming, 25030 Besançon, France 
b Convert Private Hospital, 62, avenue Jasseron, 01000 Bourg-en-Bresse, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Introduction

As population ages, the number of fractures of the proximal humerus in still-active patients is increasing. For three- or four-parts displaced fractures in which replacement is indicated, hemiarthroplasty with tuberosity reattachment remains the reference treatment; this technique, however, can lead to catastrophic functional results due to nonunion or tuberosity migration. The present study compared short-term functional results for reverse prosthesis and hemiarthroplasty in complex fractures of the proximal humerus.

Hypothesis

In selected complex proximal humerus fractures, the reverse shoulder arthroplasties is a superior treatment option.

Patients and methods

Forty patients were treated by shoulder replacement for three- or four-part displaced fractures of the proximal humerus between 1996 and 2004. Twenty-one had a hemiarthroplasty and 19 were treated by reverse prosthesis. All patients of both groups were reviewed retrospectively by an independent observer. Joint amplitude and Constant score were measured; quality of life was assessed by DASH score. Standard X-ray assessment comprised frontal imaging in three rotation positions and Lamy’s incidence.

Results

In the hemiarthroplasty group, 17 patients, mean age 74 years (range: 49–95), were followed up for a mean 16.5 months (6–55). In the reverse prosthesis group, 16 patients, mean age 74 years (range: 58–84), were followed up for a mean 12.4 months (6–18). The reverse prosthesis group showed better results in terms of abduction (mean=91° versus 60°), anterior elevation (mean=97.5° versus 53.5°) and Constant score (mean=53 versus 39). Rotation was better in the hemiarthroplasty group (external rotation, 13.5° versus 9°; internal rotation, 54.6° versus 31°). DASH scores were identical in both groups. X-ray showed three abnormal tuberosity fixations in the hemiarthroplasty group and 15 glenoid notches in the reverse arthroplasty group.

Discussion

In three- or four-part displaced proximal humerus fracture, arthroplasty does not ensure recovery of pretrauma shoulder function. Management is therefore to be decided in terms of outcome predictability and rapid recovery of daily comfort for elderly patients. Hemiarthroplasty can provide good functional results, but depends on tuberosity union quality and this often necessitates a prolonged immobilization. Reverse prostheses provide reliable, rapid and predictable results in terms of abduction, anterior elevation and pain relief, but impaired rotation; this impacts quality of life and long-term implant durability (glenoid notching). Reverse prostheses should thus prove advantageous in the treatment of complex fractures of the proximal humerus if these two drawbacks can be resolved and at present seem indicated on condition that the patient is no younger than 70 years of age.

Level of evidence: level IV; therapeutic study.

Le texte complet de cet article est disponible en PDF.

Keywords : Shoulder, Fracture, Reverse prosthesis, Hemiarthroplasty


Plan


© 2008  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 95 - N° 1

P. 48-55 - février 2009 Retour au numéro
Article précédent Article précédent
  • Knee MR-arthrography in assessment of meniscal and chondral lesions
  • L. Mathieu, A. Bouchard, J.-P. Marchaland, J. Potet, B. Fraboulet, M. Danguy-des-Deserts, G. Versier
| Article suivant Article suivant
  • RETRACTED: Proximal humerus fractures treated by percutaneous locking plate internal fixation
  • D.-M. Rouleau, G.-Y. Laflamme, G.K. Berry, E.J. Harvey, J. Delisle, J. Girard

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.