Évaluation d’une sonde spécifique HPV 16, 18 et 45 Hybrid Capture® (Digene) chez des patientes présentant une infection à HPV haut risque oncogène - 11/02/09

Doi : 10.1016/j.patbio.2008.08.002 
S. Hantz a, , E. Decroisette b, H. Caly b, J. Renaudie c, C. Dussartre d, D. Bakeland e, F. Denis a, S. Alain a
a Laboratoire de bactériologie-virologie, EA3175, CHU de Limoges, 2, avenue Martin-Luther-King, 87000 Limoges, France 
b Service de gynécologie-obstétrique, CHU de Limoges, France 
c Service de gynécologie, clinique du Colombier, Limoges, France 
d Cabinet d’anatomie pathologique Dussartre-Gilquin, Limoges, France 
e Cabinet d’anatomie pathologique Bakeland, Guéret, France 

Auteur correspondant.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 5
Iconographies 1
Vidéos 0
Autres 0

Résumé

But de l’étude

Pour les lésions à pronostic indéterminé (atypical squamous cell of undetermined significance [ASCUS]) au frottis cervicovaginal, un test de détection du génome des papillomavirus à haut risque oncogène (HPV HR) est recommandé. Le risque d’évolution vers un cancer du col diffère selon le génotype et trois génotypes (HPV 16, 18 et 45) sont retrouvés dans 77,4 % des cancers du col. Nous avons donc souhaité tester la sonde 16/18/45 (Digene) permettant d’identifier spécifiquement ces trois génotypes.

Matériel et méthodes

Cette étude a porté sur 37 patientes sélectionnées sur la base d’un résultat positif avec la sonde HPV HR Digene. La sonde 16/18/45 a été évaluée sur ces 37 patientes selon les recommandations du fabricant. Parallèlement, le typage des souches a été réalisé par séquençage (PCR GP5+/GP6+) et confrontation aux banques de données (Genbank) et par technique Inno-Lipa (Innogenetics) pour contrôler les échantillons présentant des résultats discordants.

Résultats

Parmi les 37 patientes présentant un HPV HR, 48,6 % ont eu un résultat positif avec la sonde 16/18/45 (18 patientes). Le génotypage a retrouvé 12 résultats concordants et six résultats discordants (trois HPV 31, deux HPV 58 et un HPV 59). Concernant les 19 patientes avec un résultat négatif avec la sonde 16/18/45, 18 résultats sont concordants et un discordant (HPV 18). La concordance globale entre les résultats de la sonde spécifique et ceux du séquençage pour le typage est de 81 %. L’analyse par un test κ objective une bonne concordance entre ces résultats (coefficient κ : 0,62). La valeur prédictive positive est de 66,6 % et la valeur prédictive négative de 94,7 %.

Conclusion

Cette étude montre une bonne efficacité de la sonde 16/18/45 (Digene) à détecter les génotypes les plus à risque d’induire le développement d’un cancer du col. Elle pourrait également permettre de surveiller l’épidémiologie de l’infection à HPV HR après la mise sur le marché des vaccins anti-HPV 16 et 18.

Le texte complet de cet article est disponible en PDF.

Abstract

Background

HPV HR detection test are needed when ASCUS is diagnosed on Pap test. The risk of progression to cervical cancer is dependant on the HPV genotype and three types (HPV 16, 18 and 45) are found in 77.4% of the cervical cancer. Here we have tested a new probe 16/18/45 (Digene) that is able to detect specifically these three types.

Material and methods

Thirty-seven women with a Hybrid Capture® 2 High Risk test (Digene) positive were selected to test the new probe 16/18/45. Samples were typed using sequencing reaction after GP5+/GP6+ PCR. Types were given after comparison with the GenBank. Discordant results were controlled with Inno-Lipa HPV genotyping v2 test (Innogenetics).

Results

Among the 37 women with HR HPV result, 48.6% were positive with the probe 16/18/45 (18 patients). After genotyping, 12 results were concordant and six discordant (three HPV 31, two HPV 58 et one HPV 59). For the other 19 patients with negative result, 18 are concordant and one discordant (HPV 18). Global concordance for typing between this probe and sequencing was 81% with a κ test of 0.62 that means a good concordance. Positive predictive value is 66.6% and negative predictive value is 94.7%.

Conclusion

This study shows a good efficiency of the 16/18/45 probe to detect the genotypes that have the higher risk of progression to cervical cancer. This probe could also allow to follow the epidemiology of HR HPV infection after a large use of HPV vaccines.

Le texte complet de cet article est disponible en PDF.

Mots clés : HPV, Dépistage, Génotypage, Capture d’hybrides, PCR, Hybridation

Keywords : HPV, Detection, Genotyping, Hybrid capture, PCR, Hybridization


Plan


© 2008  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 57 - N° 1

P. 81-85 - février 2009 Retour au numéro
Article précédent Article précédent
  • Place de Streptococcus pyogenes dans les angines au Maroc et état actuel de sa sensibilité aux antibiotiques
  • A. Benouda, S. Sibile, Y. Ziane, M. Elouennass, K. Dahani, A. Hassani
| Article suivant Article suivant
  • Sensibilité et spécificité du test immuno-chromatographique VIKIA® Rota-Adéno (bioMérieux) et du kit Elisa IDEIA™ Rotavirus (Dako) par rapport aux techniques de génotypage
  • A. de Rougemont, J. Kaplon, G. Billaud, B. Lina, S. Pinchinat, T. Derrough, E. Caulin, P. Pothier, D. Floret

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.