Conservation of historical reinforced concrete structures damaged by carbonation induced corrosion by means of electrochemical realkalisation - 25/11/08

Doi : 10.1016/j.culher.2008.01.006 
Luca Bertolini 1 , Maddalena Carsana 2 , Elena Redaelli
Politecnico di Milano, Dipartimento di Chimica, Materiali e Ingegneria Chimica “G. Natta”, via Mancinelli, 7, 20131 Milan, Italy 

Corresponding author. Tel.: +39 02 2399 3115; fax: +39 02 2399 3180.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 10
Iconographies 19
Vidéos 0
Autres 0

Abstract

Electrochemical realkalisation is a technique aimed at stopping rebar corrosion in carbonated concrete. The alkalinity of the concrete around the rebars is restored, and an environment favourable to the passivation of steel is re-created. The technique is based on the application of a DC current from an anode, placed on the external surface of the concrete, and the rebar. The anode is usually embedded in cellulose pulp soaked with a solution of sodium or potassium carbonate. The rebar and the anode are connected to a DC current feeder, the rebar to the negative terminal and the anode to the positive terminal. The applied current produces alkalinity at the surface of the rebar, while the alkaline electrolyte in which the anode is immersed penetrates from the external surface. In this way the concrete is realkalised, its protective characteristics towards the steel are restored and rebars can return to passive conditions. The treatment is temporary: this feature makes it very attractive in the field of historical buildings and cultural heritage, where the conservation of the original materials and surfaces is often a stringent requirement in the design of the repair. This paper shows the advantages of this technique applied to historical structures by describing the application to a bell tower built in the 1920s. The electrochemical realkalisation treatment was applied to eight columns on the bell tower where a traditional repair (based on the substitution of carbonated concrete with a repair mortar) would have been practically impossible. The application of the treatment followed two steps: initially, a trial was made on two sections of two columns, so as to calibrate the process parameters such as current density, time length and type of anode. Subsequently, the treatment was applied to all the columns. The analyses carried out on the concrete after the application of the treatment showed that the protection to the reinforcement was mainly connected to the alkaline layer produced around the steel, which is expected to prevent further corrosion of the steel.

Le texte complet de cet article est disponible en PDF.

Keywords : Reinforced concrete, Carbonation, Concrete, Corrosion, Electrochemical realkalisation, Conservation, Historical buildings


Plan


© 2008  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 9 - N° 4

P. 376-385 - septembre-décembre 2008 Retour au numéro
Article précédent Article précédent
  • Silicatescape – preserving building materials in the old urban center landscape: The case of the silicate brick and urban planning in Tel Aviv-Jaffa
  • Irit Amit-Cohen
| Article suivant Article suivant
  • A new class of gels for the conservation of painted surfaces
  • Emiliano Carretti, Luigi Dei, Richard G. Weiss, Piero Baglioni

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.