Jacketed respiratory inductive plethysmography in rats: A translational non-invasive method for cardiorespiratory exercise monitoring - 08/04/25

Doi : 10.1016/j.rmr.2025.02.090 
A. Cambier 1, 2, , S. Tanguy 1, T. Flenet 2, F. Boucher 1
1 Physiologie cardio-respiratoire expérimentale théorique et appliquée, TIMC, University Grenoble Alpes, France 
2 R&D département, ETISENSE, Lyon, France 

Corresponding author.

Résumé

Introduction

Respiratory inductive plethysmography (RIP) is one of the least restrictive methods for evaluating pulmonary ventilation. It has been used in humans since the 1980s as one of the clinical tests for functional exploration of the respiratory system under different conditions (sleep, rest or exercise) in healthy and in respiratory pathology patients. This method has been adapted and integrated into jacketed telemetry systems used in preclinical large animal research (safety pharmacology, fundamental or applied research, etc.). Thanks to the recent miniaturisation of jacketed telemetric systems, a new solution is available for assessing respiratory function combined with ECG in small mammals [1] (i.e. rats). As exercise was initially used to validate the measurement accuracy of dual-band respiratory inductance plethysmography in humans, it was of interest to qualify this solution in a similar way in rats. The aim is to assess the feasibility of a translational model using this technology to monitor physiological changes associated with exercise on a treadmill.

Methods

For this purpose, male Wistar rats (n=10.8-9 weeks old) were exposed to an incremental treadmill exercise protocol with speed levels from 5 to 45cm. s-1. Respiratory parameters (respiratory rate (RespR), minute ventilation (VM), Tidal volume (VT)) and peak inspiratory and expiratory flow (PIF, PEF, PENH) as well as cardiac (heart rate (HR)) and activity level (AL) were continuously monitored and analyzed over the last 30seconds of each level.

Results

All animals were successfully fitted with the device and returned to their home cages. The control values measured after stabilization were for RespR 165±8brpm, HR 407±9bpm and AL 24±4mg. At least all animals ran successfully on the treadmill with the vest up to 35cm/sec (n=10), some reaching 45cm/sec (n=6). For the maximum plateau, exercise induced a significant physiological increase (Figure 1) in respiratory parameters (RespR +74%, 116±26 brpm, P<0.01**//MV +334%, 1099±197mL. min-1, P<0.01**//VT +197%, 4±1mL, P<0.01**), as well as HR (+36%, 140±13 bpm, P<0.05*) and AL (+2358%, 504±57 bpm, P<0.05*). PIF and PEF showed a significant increase of 86±9ml. s-1 and 52±11mL. s- respectively. enhanced Pause (PENH) remained stable during exercise indicating no significant variation of airflow limitation.

Conclusion

In conclusion, this new telemetry jacket can be used to monitor the adaptation of respiratory parameters during a standard forced exercise protocol and in a non-invasive way in rats. It is convenient to use and well tolerated by the animal. This alternative method could be used to refine respiratory monitoring in exercise protocols and offers new perspectives for studying pathological and/or pharmacological phenotype alterations in various models.

Le texte complet de cet article est disponible en PDF.

Plan


© 2025  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 42 - N° 4

P. 227 - avril 2025 Retour au numéro
Article précédent Article précédent
  • Chronic and intermittent hypoxias lead to disrupted clock genes expression in mouse lung tissues: Implications for lung cell senescence
  • V. Gros, E. arcos, J. Jacquet, E. Born, J.A. De Freitas, S. Abid, D. Beaulieu, N. Vienney, A. Houssaini, L. Lipskaia, C. Jourdan Le Saux, O. Bischof, H. Duez, B. Pourcet, L. Boyer, S. Adnot
| Article suivant Article suivant
  • Une méthode simple pour dépister la distension dynamique pulmonaire : le test de tachypnée rythmée par un métronome
  • G. Simon, J. Moulinié, Q. Lorber, M. Hayot, F. Gouzi

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.