Élaboration et validation d’un nouveau dispositif de surveillance des pressions plantaires : application à la décharge du pied - 19/06/08

Doi : 10.1016/j.annrmp.2008.01.007 
V. Femery a, F. Potdevin a, c, A. Thevenon b, P. Moretto a, , d
a Laboratoire d’études de la motricité humaine, faculté des sciences du sport et de l’éducation physique, EA 3608, université du droit et de la santé de Lille-2, 9, rue de l’Université, 59790 Ronchin, France 
b Service de médecine physique et de réadaptation, hôpital Swynghedauw, centre hospitalier régional universitaire de Lille, Lille, France 
c Unité de recherche sur l’évolution des comportements et des apprentissages, université Charles-de-Gaulle, B.P. 149, 59653 Villeneuve d’Ascq cedex, France 
d Laboratoire d’automatique, de mécanique et d’informatique industrielles et humaines, UMR-CNRS 8530, Valenciennes, France 

Auteur correspondant.

Résumé

Objectifs

Valider un nouvel appareil de surveillance des pressions plantaires capable de détecter, en temps réel, des hyperpressions et permettre à l’utilisateur un autocontrôle des évènements dynamiques à l’interface pied–chaussure–sol. Le but de cette étude est de vérifier la faisabilité d’une décharge intentionnelle et partielle de la première tête métatarsienne.

Matériel et méthode

Huit sujets sains sont équipés de capteurs de pression plantaire intégrés à des semelles individualisées. Les sujets ont pour consigne de soulager la mise en charge sous la première tête métatarsienne du pied droit. Le seuil de décharge est fixé à −5 % du pic de pression enregistré en condition standard. Suivant les essais, des signaux visuels et sonores informent le sujet d’une décharge excessive, insuffisante ou correcte.

Résultats

Cinq sujets sur huit parviennent à modifier significativement leur patron de marche et soulager la mise en charge de 5 % sous la première tête métatarsienne. La décharge est effective dans 70,7 % des cas. Toutefois, les sujets ont spontanément tendance à décharger la première tête métatarsienne au-delà du seuil imposé (48,2 % des cas).

Discussion – conclusion

Les résultats montrent la faisabilité d’une décharge intentionnelle et partielle du pied par biofeedback, mais soulignent la difficulté des sujets à maîtriser un contrôle fin et précis de cette décharge. La réadaptation par biofeedback baropodométrique est centrée sur les capacités de transformation du comportement locomoteur du sujet. Elle pourrait être utilisée dans la prévention primaire et secondaire des maux perforants plantaires des patients diabétiques.

Le texte complet de cet article est disponible en PDF.

Abstract

Objective

To validate a new plantar pressure control device able to detect excessive plantar pressure on-line and to improve the subjectʼs awareness of the gait pattern in order to correct and optimize the load distribution patterns. The aim of this study was to verify the feasibility of a deliberate and partial unload of the first metatarsal head.

Material and method

Eight healthy subjects were equipped with the plantar pressure sensors integrated in customized insoles. They were told to unload the first metatarsal head of the right foot by 5%. During the trials, the auditory and visual signals inform the subject of an excessive, insufficient or correct unload.

Results

Five subjects over eight succeeding in modifying significantly their gait pattern and in unloading by 5% the first metatarsal head. The unload is effective in 70.7% of the trials. However, the subjects were spontaneously inclined to reduce peak pressure under the first metatarsal head beyond the critical peak plantar pressure threshold (48.2% of the trials).

Discussion – conclusion

The results showed the feasibility of a partial and deliberate foot unloading in using biofeedback device but emphasized the subjectʼs difficulty to control a discriminated and accurate unload of the first metatarsal head. That points out the necessity of learning period. The baropodometric biofeedback rehabilitation focuses on the subjectʼs capacities to modify its own locomotor pattern. It would be used as primary and secondary prevention means of diabetic foot ulceration.

Le texte complet de cet article est disponible en PDF.

Mots clés : Marche, Pressions plantaires, Contrôle moteur, Décharge du pied, Biofeedbacks

Keywords : Gait, Plantar pressure, Motor control, Foot unloading, Augmented sensory feedback


Plan


© 2008  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 51 - N° 4

P. 231-237 - mai 2008 Retour au numéro
Article précédent Article précédent
  • La nouvelle politique de la Sofmer en matière de recherche
  • P. Thoumie
| Article suivant Article suivant
  • Intérêt de la thérapie par contrainte induite chez l’enfant hémiplégique après lésion cérébrale acquise
  • M. Chevignard, V. Azzi, G. Abada, C. Lemesle, S. Bur, H. Toure, D.G. Brugel, A. Laurent-Vannier

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.