Cone-beam CT radiomics for early response assessment in liver stereotactic body radiation therapy: Results of a pilot study - 28/03/25

Doi : 10.1016/j.canrad.2024.05.010 
Jingjing Shan a, 1, Pengfei Yang a, b, c, 1, Eric Yen a, c, Qinxuan Zhou a, Benxing Gu a, Xuyun Xie a, Jing Wang a, c, Tianye Niu a, c, , Xiaonan Sun a,
a Department of Radiation Oncology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China 
b College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China 
c Institute of Translational Medicine, Zhejiang University, Hangzhou, Zhejiang, China 

Corresponding authors. Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, Zhejiang, China.Sir Run Run Shaw Hospital, Zhejiang University School of MedicineHangzhouZhejiangChina

Abstract

Purpose

The objective of the study was to assess the correlation between radiomics features extracted from cone-beam CT with the treatment response of liver tumors treated with stereotactic body radiation.

Material and methods

The planning CT and cone-beam CT were prospectively collected for 76 patients with liver cancer who received five fractions of stereotactic body radiation therapy. Pearson correlation test was used to identify interchangeable radiomics features between cone-beam- and planning CT from a total of 547 extracted radiomics features. Principal components analysis was used for cone-beam CT delta radiomics to characterize therapy-induced tumor change. The Mann-Whitney U-test was used to identify features with correlation to treatment response: local efficacy versus local non-efficacy; complete versus partial response in both raw and principal components analysis-based cone-beam CT radiomics features. The area under the receiver operating characteristic curve was used for assessing feature performance.

Results

A total of 345 cone-beam CT radiomics features were interchangeable with planning CT. The mean value of LHH_GLSZM_LGZE showed an ascending trend in five fractions during the course of treatment. Among these features, PCA3_LHH_Histogram_Energy showed the best performance in predicting local efficacy, with an AUC of 0.879 (0.744–1.00, 95 % CI). For identifying complete response from partial response, CBCT2_LHL_GLSZM_GLV showed the best value, with the highest AUC of 0.884 (0.773–1.00, 95 % CI).

Conclusion

Radiomics features extracted from cone-beam CT images have the potential for assessing the response to treatment in advance and can serve as an early biomarker for liver tumor stereotactic body radiation therapy.

Le texte complet de cet article est disponible en PDF.

Keywords : Liver tumor, Cone-beam computed tomography, Radiomics, Stereotactic body radiation therapy

Abbreviations : CBCT, SBRT, pCT, CR, PR, PCA, HCC, LC, RECIST, mRESCIST, EASL, MRI, OAR, NSCLC, GTV, VOI, OBI, GLCM, GLRLM, GLSZM, NGTDM, PD, SD, ROC, AUC, PTV, BED, ORR, RILD


Plan


© 2025  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 29 - N° 1

Article 104586- février 2025 Retour au numéro
Article précédent Article précédent
  • Does prior radiotherapy impact the acute cellular liver graft rejection?
  • Julien Pierrard, Maxime Foguenne, Pamela Baldin, Eliano Bonaccorsi-Riani, Laurent Coubeau, Olga Ciccarelli, Géraldine Dahlqvist, Bénédicte Delire, Geneviève Van Ooteghem
| Article suivant Article suivant
  • Association between radiotherapy and risk of secondary primary malignancies in patients with esophageal cancer: A population-based study utilizing 17 Surveillance, Epidemiology, and End Results cancer registries
  • Wenjie Li, Wei Wang

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.