S'abonner

Randomized comparison of the combined Sirolimus eluting and endothelial progenitor cell combo Stent vs. biolimus eluting absorbable polymer coated biomatrix alpha stent in patients undergoing percutaneous coronary intervention: Rationale and study design of the Scandinavian Organization for randomized trials with clinical outcome (SORT OUT) XI trial - 03/03/25

Doi : 10.1016/j.ahj.2025.01.012 
Ashkan Eftekhari, MD PhD a, , Evald Høj Christiansen, MD PhD b, Jens Flensted Lassen, MD PhD c, d, Bent Raungaard, MD PhD a, Lars Jakobsen, MD PhD b, Lisette Okkels Jensen, MD DMSci PhD c, d
a Department of Cardiology, Aalborg University Hospital, Aalborg, Denmark 
b Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark 
c Department of Cardiology, Odense University Hospital, Odense, Denmark 
d Department of Clinical Research, University of Southern Denmark, Odense, Denmark 

Reprint requests: Ashkan Eftekhari MD PhD, Department of Cardiology, Aalborg University Hospital, Hobrovej 18-22, 9000 Aalborg, Denmark.Department of CardiologyAalborg University HospitalHobrovej 18-22Aalborg9000Denmark

ABSTRACT

Rationale

The biodegradable polymer Biomatrix Alpha stent contains biolimus A9 drug which is a sirolimus derivative increased in lipophicity. The biodegradable polymer sirolimus eluting Combo stent is a dual-therapy sirolimus-eluting and CD34+ antibody coated stent capturing endothelial progenitor cells (EPCs).

Hypothesis

The main hypothesis of the SORT OUT XI trial was that the biodegradable polymer biolimus A9 Biomatrix Alpha stent is noninferior to the biodegradable polymer sirolimus eluting Combo stent in an all-comers population with coronary artery disease undergoing percutaneous coronary intervention (PCI).

Methods

The SORT OUT XI study was a randomized, multicenter, single blinded, all-comer, 2-arm, noninferiority trial comparing the biodegradable polymer biolimus A9 Biomatrix Alpha stent to the biodegradable polymer sirolimus eluting Combo stent in 3 Danish University Hospitals in Western Denmark. The composite primary endpoint was target lesion failure (TLF) within 12 months. TLF was defined as composite of cardiac death, myocardial infarction not related to other than index lesion or target lesion revascularization. Clinically driven event detection was used and no planned follow up was performed. With a sample size of 1,564 patients in each treatment arm, a 2-group large-sample normal approximation test of proportions with a 1-sided 5% significance level had a 90% power to detect noninferiority with a predetermined noninferiority margin of 2.1%.

Results

The trial ran from August 14, 2019 to March 19, 2023. A total of 3141 patients were enrolled and randomized 1:1 to Combo stent (n = 1,573) and Biomatrix Alpha stent (n = 1,568).

Conclusion

The SORT OUT XI trial will assess if the biolimus A9 eluting Biomatrix Alpha stent is noninferior to the dual-therapy Combo stent with respect to target lesion failure.

ClinicalTrials.gov

NCT03952273.

Le texte complet de cet article est disponible en PDF.

Plan


© 2025  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 283

P. 37-42 - mai 2025 Retour au numéro
Article précédent Article précédent
  • Rationale and design of the prevail global trial program evaluating the prevail drug-coated balloon in patients with in-stent restenosis and de novo small vessel disease
  • David E. Kandzari, Azeem Latib, Darren Mylotte, Ziad A. Ali, Azfar Zaman, Sandeep Brar, Maria Parke, Bruno Scheller
| Article suivant Article suivant
  • Study protocol for the healthy family program on population blood pressure: A multicenter, parallel group, cluster randomized, controlled trial in rural China
  • Yangyang Tang, Chao Jiang, Jiakun Guo, Yueyuan Li, Chi Wang, Shuk Han Chu, Zhiyan Wang, Yanfang Wu, Chang Hua, Yanmei Lu, Shuai Zhang, Yanna Song, Rong Han, Jianzeng Dong, Changsheng Ma, Jun Cai, Craig S. Anderson, Xin Du

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.