S'abonner

Comparison of Different Sensor Locations on Freezing-of-Gait Ratio Results - 18/02/25

Doi : 10.1016/j.irbm.2025.100881 
Slavka Netukova a, , Lucie Horakova a, b , Evžen Růžička b , Petr Dusek b , Zoltan Szabo a , Radim Krupička a
a Faculty of Biomedical Engineering, Czech Technical University in Prague, nam Sitna 3105, Czech Republic 
b Department of Neurology and Centre of Clinical Neuroscience, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic 

Corresponding author.

Abstract

Background

Freezing of gait (FoG) is a walking disturbance in the Parkinson's disease (PD). The freezing ratio (FoG-ratio) is a parameter used to quantify overall freezing severity rather than to assess single freezing episodes. Originally the FoG-ratio was designed to be computed from lower limb acceleration. However, some available measurement systems get their data from a single sensor located elsewhere, e.g. on the lower back.

Purpose

The objective of our paper is to analyse whether acceleration signals measured on different body locations result in a consistent FoG-ratio.

Methods

Eighty-four people with PD and 65 people without neurological disorders completed an instrumented Timed Up&Go Test (iTUG) twice. The FoG-ratios from inertial units placed on the chest, lower back, left and right lower limbs were calculated.

Findings

There were significant differences between the tested FoG-ratios in the control group as well as in the PD group for both segments. Four significant, but not consistent, correlations were revealed for the turn segment in the PD group. Eight correlations were revealed in the control group. The inter-trial reliability of all the tested cases for gait was good (rho>0.75) but only in one case for turning.

Conclusion

In conclusion, the placement of sensors affected the FoG-ratio parameter output. The different FoG-ratios reflect different amounts of power in the locomotion band of body segments. This could result in inconclusive validity and incomparability of freezing severity presented in studies when the sensor is placed somewhere other than on the lower limbs.

Le texte complet de cet article est disponible en PDF.

Graphical abstract

Le texte complet de cet article est disponible en PDF.

Highlights

The freezing ratio (FoG-ratio) was developed to quantify overall freezing severity.
The FoG-ratio was designed to be computed from lower limb acceleration.
FoG-ratios from other body locations differ from lower limb FoG-ratio during turn.

Le texte complet de cet article est disponible en PDF.

Keywords : Freezing of gait, Wearable sensor, Accelerometer, Freezing severity, Inertial measurement unit


Plan


© 2025  AGBM. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 46 - N° 2

Article 100881- avril 2025 Retour au numéro
Article précédent Article précédent
  • Contents
| Article suivant Article suivant
  • Objective Assessment of Pull Test Scores in Parkinson's Disease Under Dynamic Conditions
  • Marta Cardoso, Cristiana Pinheiro, Helena R. Gonçalves, Ana Margarida Rodrigues, Cristina P. Santos

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.