Retraitement des dispositifs médicaux à usage unique: Points de vue et perceptions des cardiologues et pharmaciens hospitaliers - 29/01/25

Reprocessing of Single-Use Medical Devices: Viewpoints and Perceptions of Cardiologists and Hospital Pharmacists

Doi : 10.1016/j.pharma.2025.01.011 
Samantha Huynh 1, Adeline Bonan 1, Judith Pineau 1, Eloi Marijon 2, Brigitte Sabatier 1, Nicolas Martelli 1, 3,
1 Service de Pharmacie, Hôpital Européen Georges Pompidou, AP-HP, 20 rue Leblanc, 75015, Paris, France 
2 Service de Cardiologie, Hôpital Européen Georges Pompidou, AP-HP, 20 rue Leblanc, 75015, Paris, France 
3 Université Paris-Saclay, GRADES, Faculté de Pharmacie, 17 Avenue des Sciences, 91190, France 

Auteur correspondant: Service Pharmacie, Hôpital Européen Georges Pompidou, AP-HP, 20 rue Leblanc, 75015, Paris, FranceService Pharmacie, Hôpital Européen Georges Pompidou, AP-HP, 20 rue LeblancParis75015France
Sous presse. Manuscrit accepté. Disponible en ligne depuis le Wednesday 29 January 2025
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Résumé

Une expérimentation sur le retraitement des dispositifs médicaux (DM), notamment en électrophysiologie, sera lancée en France en novembre 2024.

Notre enquête a pour objectif de comparer les connaissances et les positions des pharmaciens hospitaliers (PH) et des cardiologues (CA) sur l’utilisation de DM à usage unique retraités (DMUUR), afin d'identifier leurs préoccupations ainsi que les points de convergence et de divergence. Un questionnaire électronique, directif et mixte composé de 27 questions a été envoyé aux PH et aux CA de l’Assistance Publique-Hôpitaux de Paris (AP-HP). Les réponses de 32 PH et 30 CA ont été analysées en utilisant le logiciel R.

Les CA se prononcent unanimement en faveur du retraitement tandis que les PH expriment davantage de réserves (p<0,0001). Pour 56 % (n=18) des PH, le circuit « ouvert » serait à privilégier, tandis que 28 % (n=9) optent pour un circuit « fermé ». Les CA montrent une répartition plus équilibrée de leurs préférences, avec 30 % (n=9) favorisant le circuit « ouvert » et 40 % (n=12) le circuit « fermé ». Cette pratique suscite des préoccupations quant à la sécurité et la qualité des dispositifs retraités, tant chez les PH que chez les CA. La majorité des participants sont néanmoins ouverts à l’utilisation de DMUUR sous certaines conditions strictes de validation, telles que la preuve d’études cliniques évaluant l’efficacité du DMUUR par rapport au DM initial. Le retraitement est toutefois perçu comme un levier pour réduire les coûts et l'empreinte carbone à l’hôpital.

Le texte complet de cet article est disponible en PDF.

Abstract

A pilot initiative on the reprocessing of medical devices (MD), particularly in electrophysiology, is expected to be launched in France in November 2024. Reprocessing single-use medical devices (SUDs) presents potential benefits and challenges, with differing perspectives among healthcare professionals.

This study aims to compare the knowledge and positions of hospital pharmacists (HP) and cardiologists (CA) regarding the use of reprocessed single-use devices (R-SUDs), in order to identify their concerns as well as points of convergence and divergence. A directive and mixed electronic questionnaire consisting of 27 questions was sent to HPs and CAs from the Assistance Publique-Hôpitaux de Paris (AP-HP). Responses from 32 HPs and 30 CAs were analyzed using statistical methods via R software. The results revealed that CAs overwhelmingly support reprocessing, while HPs show significantly more reservations (p<0.0001). Among HPs, 56% (n=18) favored an "open" supply chain model for reprocessing, compared to 28% (n=9) who preferred a "closed" one. CAs show a more balanced distribution of their preferences, with 30% (n=9) favoring the “open” chain and 40% (n=12) the “closed” model.

Both groups raised concerns about the safety and quality of reprocessed devices, but the majority would accept R-SUDs if clinical trials validated their safety and effectiveness compared to original SUDs. Reprocessing is nevertheless seen as a means to reduce hospital costs and carbon footprint in hospitals.

Le texte complet de cet article est disponible en PDF.

Mots-clés : Dispositifs médicaux, Cardiologie, Développement durable, Sécurité des dispositifs retraités

Keywords : Medical devices, Cardiology, Sustainable development, Safety of reprocessed devices



© 2025  Académie Nationale de Pharmacie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.