ABSTRACT

Study Objective

This study aimed to assess the practical application of conventional 2D pelvic ultrasound in conjunction with 3D ultrasound for evaluating obstructive Müllerian abnormalities.

Design

Retrospective study in a tertiary referral hospital

Methods

Computerized stored data were used to collect surgically confirmed obstructive Müllerian anomaly cases between December 2022 and October 2023 with evaluation of presurgical imaging. Acute presentation with abdominal pain and clinical suspicion of an obstructive Müllerian abnormality were required for inclusion. All study participants underwent pelvic ultrasound before the definitive surgery, with or without a repeat MRI if one was performed before admission. Those situations where both MRI and ultrasound were not conducted were excluded, such as transverse vaginal septum, imperforate hymen, iatrogenic cervical injury, or Müllerian malformation alone without obstructive outflow anomalies such as didelphys, bicornuate, or septate uterus.

Main Outcome Measures

Concordance between the surgically confirmed diagnosis and the pelvic ultrasound was reported in 27 of 29 women (93.1%). In contrast, only 24 of 29 cases were correctly diagnosed with MRI in this study (82.8%). This pilot study presents a comparison of 2 techniques, with a specific focus on obstructive Müllerian anomalies. The use of pelvic ultrasound not only assisted in our surgical practice but also significantly improved patient-doctor counseling.

Conclusion

In managing obstructive Müllerian abnormalities, 3D-enhanced conventional pelvic ultrasound was found to be effective in diagnosis and was comparable to MRI.

Le texte complet de cet article est disponible en PDF.

Key Words : 3D US, Three-dimensional ultrasound, Obstructive Müllerian anomalies, Magnetic resonance, MRI


Plan


© 2024  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.