S'abonner

The effect of the guide hole height on the accuracy of implant placement: An in-vitro study - 17/01/25

Doi : 10.1016/j.jormas.2025.102232 
Soohyeon Kim a, 1, Jin-yong Cho b, 1, Jaeyoung Ryu a, c,
a School of Dentistry, Chonnam National University, Gwangju, Republic of Korea 
b Department of Oral and Maxillofacial Surgery, Gachon University College of Medicine and Gachon University Gil Medical Center, Incheon, Republic of Korea 
c Department of Oral & Maxillofacial Surgery, Chonnam National University Hospital, Gwangju, Republic of Korea 

Corresponding author at: Department of Oral & Maxillofacial Surgery, School of Dentistry, Dental Science Research Institute, Chonnam National University, 77, Yongbong-ro, Buk-gu, Gwangju, 61186, Republic of Korea.Department of Oral & Maxillofacial SurgerySchool of DentistryDental Science Research InstituteChonnam National University77, Yongbong-ro, Buk-guGwangju61186Republic of Korea
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Friday 17 January 2025

Abstract

Objective

Guided implant surgery using three-dimensional (3-D) planning software and 3-D printed surgical guides has become a critical tool for enhancing accuracy. This study aims to determine the minimum guide hole height necessary to maintain implant placement accuracy.

Materials and methods

Ten maxillary models with edentulous areas were created using CT and optical scan data. Six sites (for each model) were prepared for implant placement with surgical guides fabricated using a 3-D printer. Sixty implants were placed using these guides and divided into five groups according to the guide hole height (1 to 5 mm). After the placement, digital impressions were taken to assess the accuracy of implant positioning. Deviations between planned and actual implant positions were investigated using computer software, and data were statistically analyzed using ANOVA and Kruskal-Wallis tests.

Results

Guide holes with 1 mm height (Group Ⅰ) resulted in the highest 3-D deviations (1.12 ± 0.36 and 1.99 ± 0.74 mm at the coronal and apical positions, respectively), with significant errors at the implant apical position compared to groups with taller guide holes (Groups Ⅳ and Ⅴ) (p = 0.005). There were no significant deviations between the 3 mm and 5 mm guide hole heights, with no statistical differences between groups at the x, y, and z-axis in the implant position.

Conclusion

A comparison between the group with a guide hole height of 5 mm on one side and the group with a height of 1 mm on both sides revealed a significant difference in implant placement accuracy.

Le texte complet de cet article est disponible en PDF.

Keywords : Accuracy, Dental implant, Implant guide


Plan


© 2025  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.