S'abonner

L’utilisation du laser Thulium dans la fragmentation des calculs intrarénaux est-elle réellement plus efficace dans des conditions cliniques habituelles ? - 27/12/24

Is the Thulium laser really more effective for the treatment of kidney stones by flexible ureteroscopy under usual clinical conditions?

Doi : 10.1016/j.fpurol.2024.10.004 
Y. Lamboley a, , F. Bardet a, L. Sejourne a, A. Escoffier a, M. Marchand b, L. Cormier a
a Pôle médico-chirurgical digestif endocrinien et urologique, CHU de Dijon, 14, rue Paul-Gaffarel, 21033 Dijon, France 
b Centre Georges-François-Leclerc Dijon, Bourgogne-Franche-Comté, 1, rue Professeur-Marion, BP 77 980, 21079 Dijon, France 

Auteur correspondant : Service d’urologie, CHU de Dijon François-Mitterand, 14, rue Paul-Gaffarel, 21033 Dijon, France.Service d’urologie, CHU de Dijon François-Mitterand14, rue Paul-GaffarelDijon21033France
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Friday 27 December 2024

Résumé

Introduction

Il est actuellement recommandé de traiter les calculs ne pouvant être extraits directement en urétéroscopie souple en utilisant un laser. Le laser Holmium : YAG (Ho : YAG) était le laser de référence mais depuis quelques années le Thulium fibré (TFL) s’est démocratisé et commence à s’imposer avec l’avantage d’un traitement plus rapide. L’objectif de notre étude était de comparer la vitesse de pulvérisation du TFL et de l’Ho : YAG en pratique courante.

Méthodes

Nous avons réalisé une étude observationnelle multicentrique rétrospective des patients pris en charge par urétéroscopie souple pour calculs rénaux entre décembre 2020 et février 2022. Les centres étaient équipés de Ho : YAG ou TFL. Les données peropératoires ont été recueillies de manière prospective. Les patients exclus sont ceux pour lesquels le scanner préopératoire n’était pas disponible, ou encore ceux chez qui une extraction simple par panier a été réalisée. Le critère de jugement principal de notre étude était la vitesse de pulvérisation en mm3/min. Les critères de jugement secondaires étaient : la durée opératoire totale, le taux de complication, la durée de lithotritie, l’énergie totale délivrée, la consommation d’énergie.

Résultats

Au total 75 patients ont été inclus. 45 dans le groupe TFL et 30 dans le groupe Ho : YAG. La vitesse de pulvérisation était significativement supérieure dans le groupe TFL à 63 mm3/min contre 34,3 mm3/min dans le groupe Ho : YAG (p = 0,032). L’énergie délivrée par mm3 de lithiase était plus élevée dans le groupe TFL (p = 0,043). Les autres critères de jugement secondaire n’étaient pas significativement différents. En analyse multivariée, seule l’utilisation du laser TFL était significativement associée à une vitesse de fragmentation plus élevée.

Conclusion

La vitesse de pulvérisation des calculs est deux fois plus rapide avec le TFL en situation clinique usuelle.

Le texte complet de cet article est disponible en PDF.

Summary

Introduction

During flexible ureteroscopy, laser represents the preferred option to treat urinary stones. Laser fragmentation by flexible ureteroscopy is recommended for the treatment of kidney stones. The Holmium: YAG is currently the gold standard for the treatment of the urologic stones. Since few years, the use of the Thulium fiber laser has become more widespread and appears to be more efficient and faster than the Ho: YAG. We aimed to compare TFL and Ho: YAG's ability to fragment and dust kidney stones during flexible ureteroscopy.

Materials and methods

In this multicenter observational retrospective study, patients with kidney stones treated by flexible ureteroscopy and laser (Ho: YAG, TFL) were included between December 2020 and February 2022. Centers were equipped with Holmium: YAG of Thulium fiber lasers. Excluded patients are those for whom preoperative CT scans were not available, or those who underwent a simple basket extraction. Our primary endpoint was ablation speed expressed in mm3/min. Secondary endpoints were total operating time, complication rate, lithotripsy time, total energy delivered and energy consumption.

Results

75 patients were included. Among them, 30 were treated with the Ho: YAG laser and 45 were treated with the TFL. The ablation speed was significantly higher in the TFL group compared to the Ho: YAG group (63,2mm3/min versus 34,3, P = 0,023). The energy delivered per mm3 was significantly higher in the TFL group (P = 0,043). Other secondary outcomes were not significantly different. In multivariate analysis, only the use of the Thulium laser was associated with higher ablation speed.

Conclusion

Ablation speed is twice as fast with the TFL in typical clinical settings.

Le texte complet de cet article est disponible en PDF.

Mots clés : Urétéroscopie, Lithiase rénale, Thulium fibré, Holmium: YAG, Urologie, Laser

Keywords : Ureteroscopy, Renal stone, Laser, Urolithiasis, Thulium fiber laser, Holmium: YAG laser


Plan


© 2024  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.